Passer au contenu principal
  • Passer des commandes rapidement et facilement
  • Afficher les commandes et suivre l’état de votre expédition
  • Créez et accédez à une liste de vos produits
  • Gérer vos sites, vos produits et vos contacts au niveau des produits Dell EMC à l’aide de la rubrique Gestion des informations de l’entreprise.

Dell Chassis Management Controller Version 1.3 for PowerEdge FX2/FX2s RACADM Command Line Reference Guide

PDF

getsysinfo

Description
Displays information related to CMC and chassis.
  • NOTE: The Hostname and OS Name fields in the getsysinfo output display accurate information only if Dell OpenManage Server Administrator is installed on the managed system. Else, these fields may be blank or inaccurate. An exception to this are VMware operating system names, which are displayed even if Server Administrator is not installed on the managed system.
Synopsis
racadm getsysinfo [-d] [-c] [-A] [-4] [-6]
                                                
                                             
Input
  • -d - Displays CMC information.
  • -c - Displays chassis information.
  • -A - Does not display headers and labels.
  • -4 - Displays IPv4 information.
  • -6 - Displays IPv6 information.
Output
CMC Information:
                                                CMC Date/Time             = Tue Jan 29 2013 23:00
                                                CMC Location     				 = CMC-1
                                                Primary CMC Location      = 4.40
                                                CMC Version       			 = 1.10
                                                Last Firmware Update      = Mon Jan 28 2013 08:41
                                                Hardware Version          = A04
                                                
                                                CMC Network Information:
                                                NIC Enabled               = 1
                                                MAC Address               = D4:AE:52:AC:CA:C6
                                                Register DNS CMC Name     = 1
                                                DNS CMC Name              = cmc-servicetag
                                                Current DNS Domain        = swtest.com
                                                VLAN ID                   = 1
                                                VLAN Priority             = 0
                                                VLAN Enabled              = 0
                                                
                                                CMC IPv4 Information:
                                                IPv4 Enabled              = 1
                                                Current IP Address        = 192.168.164.115
                                                Current IP Gateway        = 192.168.164.1
                                                Current IP Netmask        = 255.255.255.0
                                                DHCP Enabled              = 1
                                                Current DNS Server 1      = 192.168.165.80
                                                Current DNS Server 2      = 0.0.0.0
                                                DNS Servers from DHCP     = 1
                                                
                                                CMC IPv6 Information:
                                                IPv6 Enabled              = 0
                                                Autoconfiguration Enabled = 1
                                                Link Local Address        = ::
                                                Current IPv6 Address 1    = ::
                                                Current IPv6 Gateway      = ::
                                                Current IPv6 DNS Server 1 = ::
                                                Current IPv6 DNS Server 2 = ::
                                                DNS Servers from DHCPv6   = 1
                                                
                                                Chassis Information:
                                                System Model              = PowerEdge FX2s
                                                System AssetTag           = 00000
                                                Service Tag               = STPST06
                                                Express Service Code      = 62746758870
                                                Chassis Name              = CMC-STPST06
                                                Chassis Location          = [UNDEFINED]
                                                Chassis Midplane Version  = 1.0
                                                Power Status              = ON
                                                System ID                 = 1488
                                                PCIe Switch Board Type    = Gen 3
                                             
  • NOTE: In the Chassis Information output, the PCIe Switch Board Type information is displayed only for PowerEdge FX2s chassis model.
Examples
racadm getsysinfo -d
racadm getsysinfo -c
racadm getsysinfo -A
racadm getsysinfo -4
racadm getsysinfo -6

Évaluez ce contenu

Précis
Utile
Facile à comprendre
Avez-vous trouvé cet article utile ?
0/3000 characters
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez indiquer si l’article a été utile ou non.
  Les commentaires ne doivent pas contenir les caractères spéciaux : <>()\