iDRAC 8/7 v2.30.30.30 User’s Guide

Configuring persistence policy settings

Using IO identity, you can configure policies specifying the system reset and power cycle behaviors that determine the persistence or clearance of the virtual address, initiator, and storage target settings. Each individual persistence policy attribute applies to all ports and partitions of all applicable devices in the system. The device behavior changes between auxiliary powered devices and non-auxiliary powered devices.

  • NOTE: The Persistence Policy feature may not work when set to default, if the VirtualAddressManagement attribute is set to FlexAddress mode on iDRAC and if the FlexAddress feature is disabled in CMC. Ensure that you set the VirtualAddressManagement attribute to Console mode in iDRAC or enable the FlexAddress feature in CMC.
You can configure the following persistence policies:
  • Virtual Address: Auxiliary powered devices
  • Virtual Address: Non-Auxiliary powered devices
  • Initiator
  • Storage target
Before applying the persistence policy, make sure to:
  • Inventory the network hardware at least once, that is, enabled Collect System Inventory On Restart.
  • Enable I/O Identity Optimization.
Events are logged to the Lifecycle Controller log when:
  • I/O Identity Optimization is enabled or disabled.
  • Persistence policy is changed.
  • Virtual address, initiator and target values are set based on the policy. A single log entry is logged for the configured devices and the values that are set for those devices when the policy is applied.

Event actions are enabled for SNMP, email, or WS-eventing notifications. Logs are also included in the remote syslogs.

Default values for persistence policy

Persistence Policy AC Power Loss Cold Boot Warm Boot
Virtual Address: Auxiliary Powered Devices Not selected Selected Selected
Virtual Address: Non-Auxiliary Powered Devices Not selected Not selected Selected
Initiator Selected Selected Selected
Storage Target Selected Selected Selected
  • NOTE: When a persistent policy is disabled and when you perform the action to lose the virtual address, re-enabling the persistent policy does not retrieve the virtual address. You must set the virtual address again after you enable the persistent policy.

Classifica questo contenuto

Preciso
Utile
Facile da comprendere
Questo articolo ti è stato d'aiuto?
0/3000 characters
  Fornisci una valutazione (1-5 stelle).
  Fornisci una valutazione (1-5 stelle).
  Fornisci una valutazione (1-5 stelle).
  Indica se l'articolo è stato utile o meno.
  I commenti non possono contenere i seguenti caratteri speciali: <>() \