Table 1. omconfig Reset Temperature Probe Thresholds . The following table describes the omconfig Reset Temperature Probe Thresholds command.

Description

Resets the minimum and maximum warning temperature thresholds back to their default values.

  • NOTE: This command is not supported on SAS controllers.

Syntax

omconfig storage enclosure action=resettempprobes controller=id enclosure=< ENCLOSUREID> index=id , where id is the controller ID and the temperature probe ID. The <ENCLOSUREID> variable specifies the enclosure.

In this syntax, n is a user-specified alphanumeric string.

Example to

Reset the thresholds for temperature probe 3, residing in the enclosure attached to connector 2 on controller 1, to the default values.

Example for SCSI, SATA, and ATA controllers

omconfig storage enclosure action=resettempprobes controller=1 enclosure=2 index=3