Event and Error Message Reference Guide for 13th Generation Dell PowerEdge ServersVersion 1.2

PDF

VLT Event Messages

VLT0100

Message
Processor module arg1 voltage is less than the lower warning threshold.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Remove the processor module. Inspect processor socket for bent pins. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

VLT0101

Message
Processor module arg1 voltage is less than the lower critical threshold.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Remove the processor module. Inspect processor socket for bent pins. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
LCD Message
Processor module <name> voltage is outside of range. Contact support
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

VLT0102

Message
Processor module arg1 voltage is greater than the upper warning threshold.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Remove the processor module. Inspect processor socket for bent pins. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

VLT0103

Message
Processor module arg1 voltage is greater than the upper critical threshold.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Remove the processor module. Inspect processor socket for bent pins. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
LCD Message
Processor module <name> voltage is outside of range . Contact support
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

VLT0104

Message
Processor module arg1 voltage is outside of range.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Remove the processor module. Inspect processor socket for bent pins. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
Processor module <name> voltage is outside of range. Contact support
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0105

Message
Processor module arg1 voltage is within range.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (VLT = Voltage)
Severity
Severity 3 (Informational)
Trap/EventID
2171
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

VLT0200

Message
The system board arg1 voltage is less than the lower warning threshold.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 2 (Warning)
Trap/EventID
2170
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

VLT0201

Message
The system board arg1 voltage is less than the lower critical threshold.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
The system board <name> voltage is outside of range. Contact support
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

VLT0202

Message
The system board arg1 voltage is greater than the upper warning threshold.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 2 (Warning)
Trap/EventID
2170
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

VLT0203

Message
The system board arg1 voltage is greater than the upper critical threshold.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
The system board <name> voltage is outside of range. Contact support
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

VLT0204

Message
The system board arg1 voltage is outside of range.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
System board voltage is outside of range. Contact support
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

VLT0205

Message
The system board arg1 voltage is within range.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (VLT = Voltage)
Severity
Severity 3 (Informational)
Trap/EventID
2171
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

VLT0206

Message
The memory module arg1 arg2 voltage is less than the lower warning threshold.
Arguments
arg1 = number, arg2 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 2 (Warning)
Trap/EventID
2170
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0207

Message
The memory module arg1 arg2 voltage is less than the lower critical threshold.
Arguments
arg1 = number, arg2 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
Memory module <number> <name> voltage is outside of range. Contact support
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0208

Message
The memory module arg1 arg2 voltage is greater than the upper warning threshold.
Arguments
arg1 = number, arg2 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 2 (Warning)
Trap/EventID
2170
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0209

Message
The memory module arg1 arg2 voltage is greater than the upper critical threshold.
Arguments
arg1 = number, arg2 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
Memory module <number> <name> voltage is outside of range. Contact support
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0210

Message
The memory module arg1 arg2 voltage is outside of range.
Arguments
arg1 = number, arg2 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
Memory module <number> <name> voltage is outside of range. Contact support
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0211

Message
The memory module arg1 arg2 voltage is within range.
Arguments
arg1 = number, arg2 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (VLT = Voltage)
Severity
Severity 3 (Informational)
Trap/EventID
2171
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

VLT0212

Message
The disk drive bay arg1 voltage is less than the lower warning threshold.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat hard disks in the bay. Reconnect all cables attached to the bay. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 2 (Warning)
Trap/EventID
2170
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0213

Message
The disk drive bay arg1 voltage is less than the lower critical threshold.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat hard disks in the bay. Reconnect all cables attached to the bay. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
Trap/EventID
2169
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0214

Message
The disk drive bay arg1 voltage is greater than the upper warning threshold.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat hard disks in the bay. Reconnect all cables attached to the bay. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 2 (Warning)
Trap/EventID
2170
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0215

Message
The disk drive bay arg1 voltage is greater than the upper critical threshold.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat hard disks in the bay. Reconnect all cables attached to the bay. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
Trap/EventID
2169
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0216

Message
The disk drive bay arg1 voltage is outside of range.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat hard disks in the bay. Reconnect all cables attached to the bay. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
Trap/EventID
2169
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0217

Message
The disk drive bay arg1 voltage is within range.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (VLT = Voltage)
Severity
Severity 3 (Informational)
Trap/EventID
2171
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

VLT0218

Message
The arg1 voltage is less than the lower warning threshold.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 2 (Warning)
Trap/EventID
2170
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

VLT0219

Message
The arg1 voltage is less than the lower critical threshold.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
The <name> voltage is outside of range. Contact support
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

VLT0220

Message
The arg1 voltage is greater than the upper warning threshold.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 2 (Warning)
Trap/EventID
2170
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

VLT0221

Message
The arg1 voltage is greater than the upper critical threshold.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
The <name> voltage is outside of range. Contact support
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

VLT0222

Message
The arg1 voltage is outside of range.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
Internal voltage is outside of range. Contact support
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

VLT0223

Message
The arg1 voltage is within range.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (VLT = Voltage)
Severity
Severity 3 (Informational)
Trap/EventID
2171
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

VLT0224

Message
The memory module arg1 voltage is less than the lower warning threshold.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 2 (Warning)
Trap/EventID
2170
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0225

Message
The memory module arg1 voltage is less than the lower critical threshold.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
Memory module <name> voltage is outside of range. Contact support
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0226

Message
The memory module arg1 voltage is greater than the upper warning threshold.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 2 (Warning)
Trap/EventID
2170
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0227

Message
The memory module arg1 voltage is greater than the upper critical threshold.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
Memory module <name> voltage is outside of range. Contact support
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0228

Message
The memory module arg1 voltage is outside of range.
Arguments
arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
Memory module <name> voltage is outside of range. Contact support
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0229

Message
The memory module arg1 voltage is within range.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (VLT = Voltage)
Severity
Severity 3 (Informational)
Trap/EventID
2171
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

VLT0230

Message
The mezzanine card arg1 arg2 voltage is less than the lower warning threshold.
Arguments
arg1 = number, arg2 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the mezzanine card. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 2 (Warning)
Trap/EventID
2170
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0231

Message
The mezzanine card arg1 arg2 voltage is less than the lower critical threshold.
Arguments
arg1 = number, arg2 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the mezzanine card. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
Trap/EventID
2169
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0232

Message
The mezzanine card arg1 arg2 voltage is greater than the upper warning threshold.
Arguments
arg1 = number, arg2 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the mezzanine card. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 2 (Warning)
Trap/EventID
2170
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0233

Message
The mezzanine card arg1 arg2 voltage is greater than the upper critical threshold.
Arguments
arg1 = number, arg2 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the mezzanine card. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
Trap/EventID
2169
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0234

Message
The mezzanine card arg1 arg2 voltage is outside of range.
Arguments
arg1 = number, arg2 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the mezzanine card. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
Trap/EventID
2169
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0235

Message
The mezzanine card arg1 arg2 voltage is within range.
Arguments
arg1 = number, arg2 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (VLT = Voltage)
Severity
Severity 3 (Informational)
Trap/EventID
2171
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

VLT0300

Message
CPU arg1 arg2 voltage is less than the lower warning threshold.
Arguments
arg1 = number, arg2 = name
Detailed Description
Low voltages may be the result of a problem with the voltage regulator or a problem with the processor. The low voltage may cause the processor to fail to operate.
Recommended Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 2 (Warning)
Trap/EventID
2170
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0301

Message
CPU arg1 arg2 voltage is less than the lower critical threshold.
Arguments
arg1 = number, arg2 = name
Detailed Description
Low voltages may be the result of a problem with the voltage regulator or a problem with the processor. When the critical threshold is crossed, the processor will fail to operate. The system may power down.
Recommended Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
CPU <number> <name> voltage is outside of range. Reseat CPU
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0302

Message
CPU arg1 arg2 voltage is greater than the upper warning threshold.
Arguments
arg1 = number, arg2 = name
Detailed Description
High voltages may be the result of problem with the voltage regulator or a problem with the processor. Elevated voltages may result in damage to the processor or other electronic components inside the system.
Recommended Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 2 (Warning)
Trap/EventID
2170
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0303

Message
CPU arg1 arg2 voltage is greater than the upper critical threshold.
Arguments
arg1 = number, arg2 = name
Detailed Description
High voltages may be the result of problem with the voltage regulator or a problem with the processor. Elevated voltages may result in damage to the processor or other system electrical components. The system may power down.
Recommended Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
CPU <number> <name> voltage is outside of range. Reseat CPU
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0304

Message
CPU arg1 arg2 voltage is outside of range.
Arguments
arg1 = number, arg2 = name
Detailed Description
Voltages outside the allowable range may damage electrical components or may cause the system to shutdown.
Recommended Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
CPU <number> <name> voltage is outside of range. Reseat CPU
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

VLT0305

Message
CPU arg1 arg2 voltage is within range.
Arguments
arg1 = number, arg2 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (VLT = Voltage)
Severity
Severity 3 (Informational)
Trap/EventID
2171
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

VLT400

Message
The arg1 sensor has failed with a value arg2 Volts.
Arguments
arg1 = sensor name, arg2 = voltage
Detailed Description
A voltage sensor identified in the message may have failed. This condition can cause system performance issues and degradation in the moitoring capability of the system.
Recommended Response Action
Do one of the following to resolve the issue: 1) Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. 2) Re-configure the system to a minimum configuration, and verify if the sensor displays a normal value, otherwise replace the system board. 3) If the sensor identified is a processor voltage sensor, remove the processor module and inspect processor socket, and replace if required. If the issue persists, contact your service provider.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
OMSA Event ID
5150
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

VLT401

Message
Unable to read arg1 sensor value.
Arguments
arg1 = sensor name
Detailed Description
A voltage sensor identified in the message may have failed. This condition can cause system performance issues and degradation in the moitoring capability of the system.
Recommended Response Action
Do one of the following to resolve the issue: 1) Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. 2) Re-configure the system to a minimum configuration, and verify if the sensor displays a normal value, otherwise replace the system board. 3) If the sensor identified is a processor voltage sensor, remove the processor module and inspect processor socket, and replace if required. If the issue persists, contact your service provider.
Category
System Health (VLT = Voltage)
Severity
Severity 2 (Warning)
OMSA Event ID
5151
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

VLT402

Message
The arg1 sensor has returned to a normal state with a value of arg2 Volts.
Arguments
arg1 = sensor name, arg2 = voltage
Detailed Description
The voltage sensor identified in the message has returned to a normal state.
Recommended Response Action
No response action is required.
Category
System Health (VLT = Voltage)
Severity
Severity 3 (Informational)
OMSA Event ID
5152
OMSA Trap ID
5152
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC     ✔*    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

VLT403

Message
The arg1 sensor state has changed to a warning state with a value of arg2 Volts.
Arguments
arg1 = sensor name, arg2 = voltage
Detailed Description
The voltage sensor identified in the message is faulty, or the voltage exceeds the preset warning threshold. This condition can cause system performance issues and degradation in the moitoring capability of the system.
Recommended Response Action
Do one of the following to resolve the issue: 1) Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. 2) Re-configure the system to a minimum configuration, and verify if the sensor displays a normal value, otherwise replace the system board. 3) If the sensor identified is a processor voltage sensor, remove the processor module and inspect processor socket, and replace if required. If the issue persists, contact your service provider.
Category
System Health (VLT = Voltage)
Severity
Severity 2 (Warning)
OMSA Event ID
5153
OMSA Trap ID
5153
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC     ✔*    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

VLT404

Message
The arg1 sensor detected an error with a value of arg2 Volts.
Arguments
arg1 = sensor name, arg2 = voltage
Detailed Description
The voltage sensor identified in the message is faulty, or the voltage exceeds the preset critical threshold. This condition can cause system performance issues and degradation in the moitoring capability of the system.
Recommended Response Action
Do one of the following to resolve the issue: 1) Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. 2) Re-configure the system to a minimum configuration, and verify if the sensor displays a normal value, otherwise replace the system board. 3) If the sensor identified is a processor voltage sensor, remove the processor module and inspect processor socket, and replace if required. If the issue persists, contact your service provider.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
OMSA Event ID
5154
OMSA Trap ID
5154
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC     ✔*    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

VLT405

Message
The arg1 sensor has failed with a value of arg2 Volts.
Arguments
arg1 = sensor name, arg2 = voltage
Detailed Description
A voltage sensor identified in the message may have failed. This condition can cause system performance issues and degradation in the moitoring capability of the system.
Recommended Response Action
Do one of the following to resolve the issue: 1) Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. 2) Re-configure the system to a minimum configuration, and verify if the sensor displays a normal value, otherwise replace the system board. 3) If the sensor identified is a processor voltage sensor, remove the processor module and inspect processor socket, and replace if required. If the issue persists, contact your service provider.
Category
System Health (VLT = Voltage)
Severity
Severity 1 (Critical)
OMSA Event ID
5155
OMSA Trap ID
5155
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC     ✔*    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

对此内容评级

准确性
有用性
易理解性
这篇文章对您有帮助吗?
0/3000 characters
  请提供评级(1-5星)。
  请提供评级(1-5星)。
  请提供评级(1-5星)。
  请选择这篇文章是否有帮助。
  注释中不得包含以下特殊字符:<>()\