iDRAC Quick Sync 2 module (optional) is located on the left control panel of the system.
Table 1. iDRAC Quick Sync 2 indicators and descriptionsThis table describes the Quick Sync status indicators. The indicator statuses are Off, which is the default state, Solid white, blinks white rapidly, blinks white slowly, blinks white five times rapidly and then powers off, solid amber, and blinking amber.
iDRAC Quick Sync 2 indicator code
Condition
Corrective action
Off (default state)
Indicates that the iDRAC Quick Sync 2 feature is powered off. Press the iDRAC Quick Sync 2 button to power on the iDRAC Quick Sync 2 feature.
If the LED fails to power on, reseat the
left control panel flex cable and check.
If the problem persists, see the
Getting help section.
Solid white
Indicates that iDRAC Quick Sync 2 is ready to communicate. Press the iDRAC Quick Sync 2 button to power off.
If the LED fails to power off, restart the system.
If the problem persists, see the
Getting help section.
Blinks white rapidly
Indicates data transfer activity.
If the indicator continues to blink indefinitely, see the
Getting help section.
Blinks white slowly
Indicates that firmware update is in progress.
If the indicator continues to blink indefinitely, see the
Getting help section.
Blinks white five times rapidly and then powers off
Indicates that the iDRAC Quick Sync 2 feature is disabled.