This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Data Center Infrastructure products. Dell carefully evaluates and monitors code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated:  July 20, 2026 ID: 000205512

This article is no longer maintained.
Updated:  June 05, 2026 ID: 000184794

SyncIQ policies fail to start due to a timeout failure, and so the policy fails.
Updated:  July 22, 2026 ID: 000165148

After a loss of power for a cluster or datacenter here is a quick checklist to validate the cluster is up and able to run as expected. This article is meant as an aid to helping the customer to determine where the issue may be after an outage if the Isilon cluster is up but unreachable.
Updated:  July 22, 2026 ID: 000212764

PowerScale: OneFS: SMB performance is degraded when mandatory packet signing is enabled.
Updated:  July 21, 2026 ID: 000065962

After upgrading OneFS to 9.5.1.5, 9.7.1.10, 9.10.1.3, or 9.12+, users may not be assigned the correct GID from a non-AD provider.
Updated:  July 20, 2026 ID: 000484180

This article describes the best practices and recommendations for client-side settings and mounts options when using the Network File System (NFS) protocol to connect to a PowerScale cluster and applies to all supported versions of OneFS.
Updated:  July 20, 2026 ID: 000063022

Nodes may encounter out-of-memory, slowdown or kernel panics as lockdata retains several gigabytes of RAM. The cause is NFS per-file instance lockdata failing to release memory on nodes.
Updated:  July 20, 2026 ID: 000418874

This article provides an overview of the PowerScale OneFS upgrade process.
Updated:  July 17, 2026 ID: 000178133

This article discusses the way to clear the Var partition as it nears capacity.
Updated:  July 16, 2026 ID: 000169344

Isilon Drive Support Package (DSP) fails during installation and returns "DSP Install Failed, 102.917784929 sec elapsed" and "ERROR: No logdata lines for 2015-03-23 12:59:40 or later"
Updated:  July 16, 2026 ID: 000075738

OneFS: Event notification: Power supply failure detected in switch xxxx on int-xxx fabric (Event ID 200020009)
Updated:  July 16, 2026 ID: 000168299

Explore the Dell End of Service Life (EOSL) and End of Life (EOL) list for converged infrastructure, storage, and storage networking products. Access End-of-Life documents for hardware, software, and firmware release and service dates
Updated:  July 15, 2026 ID: 000185734

Some PowerScale hardware procedures (such as power cycling or power draining a node) vary depending on the hardware generation. The node model name does not clearly indicate the hardware generation. Use the table below to identify your node’s hardware generation and follow the appropriate instructions in related knowledge base articles.
Updated:  July 15, 2026 ID: 000453567

How to power cycle and drain a PowerScale: Isilon node
Updated:  July 14, 2026 ID: 000020498

CloudPools services not being enabled give the error "Failed to get list of jobs: failed to read the daemon job configuration: No such file or directory."
Updated:  July 13, 2026 ID: 000159549

While applying Node Firmware package 11.6.1 on a MLK node A300/A3000/H700/H7000, A node may fail to complete rebooting due to BMC not responding after update.
Updated:  July 13, 2026 ID: 000211064

In OneFS 9.10, S3 PUT requests that include the x-amz-trailer header are rejected with an HTTP 501 (NotImplemented) error. In earlier releases, including OneFS 9.7, the same requests are accepted without error. This represents a behavioral change in S3 request validation.
Updated:  July 10, 2026 ID: 000480770

Restoring a PowerScale snapshot to a Persistent Volume Claim (PVC) does not restore all the original files.
Updated:  July 10, 2026 ID: 000210878

PowerScale Info Hub for OneFS 9.11.0.0 documentation
Updated:  July 09, 2026 ID: 000305010

How to identify if a boot flash drive has failed on 108NL, NL400, S200, X200, or X400 nodes with Event ID: 100010023 and 400120001.
Updated:  July 08, 2026 ID: 000011365

An error message "Audit system is down, request couldn't be fulfilled" appears when trying to activate a license (in offline or legacy mode).
Updated:  July 08, 2026 ID: 000486487

Dell PowerScale OneFS remediation is available for multiple security vulnerabilities that could be exploited by malicious users to compromise the affected system.
Updated:  July 07, 2026 ID: 000228207

The OneFS event 'Physical Memory low (expected xxxGB, found yyyGB)' indicates a defective DIMM module in the node, or an issue with the node's configuration.
Updated:  July 06, 2026 ID: 000032680

Kerberos authentication fails on upgrade to OneFS 8.0.0.0 from a cluster previously on OneFS 6.5.
Updated:  July 06, 2026 ID: 000065635

This article explains why one cluster in a syncIQ relationship (source or target) may report more used disk space than the other cluster. Both clusters should display identically used disk space. SyncIQ jobs are up to date.
Updated:  July 02, 2026 ID: 000214262

Nodes may panic with FAILED ASSERTION when fail to decode quota or snapshot attributes from extension blocks after upgrading to OneFS 9.2.0.0 or 9.2.1.0.
Updated:  July 02, 2026 ID: 000188137

How to preserve specific files or directories during an upgrade of OneFS.
Updated:  July 01, 2026 ID: 000093309

A faulty Dual inline memory module (DIMM) in a node may cause backend latency.