Skip to main content
PowerEdge R470 image

PowerEdge R470

PowerEdge R470

Articles

Select a category and then a related component to find articles about specific hardware and software.

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 396 shown
396 out of 396 shown

This article provides a high-level explanation for updating the BIOS and iDRAC10 firmware versions for 17th generation PowerEdge servers.
Updated:  May 23, 2026 ID: 000356005

This article provides information about the LIC008 error seen when importing the IDRAC License.
Updated:  May 23, 2026 ID: 000353269

After BIOS update on a 17G system, the Max Speed field in the System Management BIOS (SMBIOS) differs from the Central Processing Unit (CPU) spec because it reports capability, not turbo rating.
Updated:  May 24, 2026 ID: 000443098

Kioxia CM6 NVMe SSDs on 17‑generation servers experience I2C (Inter‑Integrated Circuit) communication issues. The fan speed stays locked at 100 % after OS boot. This behavior is observed on 17G servers only running Integrated Dell Remote Access Controller (iDRAC) 10 firmware version 1.20.80.51 or older.
Updated:  May 24, 2026 ID: 000430558

This article provides a high‑level guide to downloading vendor‑specific firmware and drivers for common PowerEdge NICs such as NVIDIA, Broadcom, and Intel. These processes complement Dell Update Packages (DUPs) and are used when vendor‑specific firmware or drivers are required beyond Dell’s updates.
Updated:  May 24, 2026 ID: 000423756

PowerEdge servers do not support operating system installation, or boot from direct CPU‑attached NVMe SSD drives if the metadata format size is not set to 0.
Updated:  May 24, 2026 ID: 000417881

PowerEdge connected Dell NVMe SSDs with the Limited Retry (LR) bit set may experience an increase in failures due to elevated media and data‑integrity error rates.
Updated:  May 24, 2026 ID: 000415896

Servers can stop during POST at Configuring Memory.
Updated:  May 24, 2026 ID: 000399964

PowerEdge 14G, 15G, 16G, and 17G servers skip Preboot eXecution Environment (PXE) boot when an "Unavailable" entry is last in the boot order.
Updated:  May 24, 2026 ID: 000396285

Fans reporting FAN0000/FAN0001 errors (RPM below warning or critical) should be removed and swapped to another connector; if the error follows the fan, replace it.
Updated:  May 24, 2026 ID: 000391086

Dell PowerEdge 17G servers added MEMHOT error monitoring in iDRAC10 firmware version 1.20.80.50 combined with supported Field-Programmable Gate Array (FPGA) firmware. Servers configured with Power Supply Cold Redundancy feature enabled can record random SYS565 memory temperature warning events.
Updated:  May 24, 2026 ID: 000388703

On Dell PowerEdge 17G servers using Broadcom 5719 QP OCP NX1 cards (DPN M2PYY), firmware installation fails when Secure Boot is enabled on SUSE Linux Enterprise Server (SLES). Additionally, the installed firmware version is not detected by the Operating System (OS). Disabling Secure Boot allows the firmware to install and be detected correctly.
Updated:  May 24, 2026 ID: 000388249

Dell PowerEdge 17G servers record inaccurate CPU index within iDRAC10 life cycle Log (LCLOG) and System event log (SEL) when machine check event (MCE) is recorded.
Updated:  May 24, 2026 ID: 000382576

Dell PowerEdge 17G Intel servers may record memory module temperature warning events in the Lifecycle Log and System Event Log during the server cold boot sequence.
Updated:  May 24, 2026 ID: 000381690

Dell PowerEdge Toshiba MG08 and MG09 hard drives may encounter uninterruptible Background Media Scanning (BMS), causing I/O errors, or timeouts.
Updated:  May 24, 2026 ID: 000381662

Encountering PR8 errors in the LifeCycle (LC) log when using a BlueField-3 (BF3) Data Processing Units (DPU) card (DPN: HFWRM).
Updated:  May 24, 2026 ID: 000379421

Dell Micron 7450 and 7500 Non-Volatile Memory Express solid state drives may encounter drive initialization failure due to a firmware issue, resulting in the solid state drives being unrecoverable.
Updated:  May 23, 2026 ID: 000368482

Settings are not saved in UEFI Boot Settings if more than one setting is changed.
Updated:  May 23, 2026 ID: 000366899

This article provides information about how to verify if a Network Interface Card (NIC) is compatible with a PowerEdge Server.
Updated:  May 23, 2026 ID: 000349619

This article provides information about CPU Machine Check errors and common causes and proper handling when errors are seen.
Updated:  May 23, 2026 ID: 000349127

When encryption is enabled on BOSS-N1, the system may stop during POST with the message: "No Boot Device Available or Operating System Detected."
Updated:  May 23, 2026 ID: 000342517

This article provides information about Intermittent High Fan Speeds on Dell 17G PowerEdge Servers with NVIDIA ConnectX-6 OCP Cards installed.
Updated:  May 23, 2026 ID: 000334522

Unsure about the procedure to update a specific component's firmware in a PowerEdge system? Learn how to in this specific article.
Updated:  May 23, 2026 ID: 000333712

Dell PowerEdge 17th Generation Servers: A rare issue exists with Delta power supplies (PSU) that causes a PSU mismatch.
Updated:  May 23, 2026 ID: 000328861

New deployments of OpenManage Enterprise 4.4.0 are experiencing service failures after configuring the time zone for GMT +02:00 Helsinki, Kyiv, Riga, Sofia, Tallinn, Vilnius. The issue is only seen on fresh deployment of OpenManage Enterprise (OME) 4.4.0 on Hyper-V. Deploying OpenManage Enterprise (OME) on other hypervisors is not impacted.
Updated:  May 23, 2026 ID: 000326459

R7725, R6725, R7715, and R6715 the number of CPU Cores is not recognized correctly.
Updated:  May 23, 2026 ID: 000321587

Dell PowerEdge 17G servers that shipped before March 24, 2025 will prompt for Liquid Cooling capability after updating iDRAC10 firmware.
Updated:  May 23, 2026 ID: 000319232

Dell Enterprise NVMe solid state drives may be leveraged as a substitute for Dell Data Center NVMe solid state drives.
Updated:  May 23, 2026 ID: 000315161

PowerEdge: Dell service support for end of industry production of 2.5" 15k RPM SAS hard drives
Updated:  May 23, 2026 ID: 000314166

Dell Technologies advises against downgrading Hard Drive or SSD firmware, except in validated scenarios, due to unpredictable results and version reporting issues.
Updated:  May 23, 2026 ID: 000311902