Articles
Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*
30 out of 1678 shown
1678 out of 1678 shown
The rules for accounts and passwords implemented by VxRail are explained in this article. Recommendations for VxRail account naming including vCenter ESXi host, VxRail Manager, and Platform Services Controller (PSC) root accounts, general suggestions for accounts password best practices for use in Dell VxRail.
Updated: July 24, 2026
ID: 000158231
Resolutions for common issues that may occur while running VxVerify to precheck a Dell VxRail upgrade.
Updated: July 22, 2026
ID: 000066460
Explore the Dell End of Service Life (EOSL) and End of Life (EOL) list for converged infrastructure, storage, and storage networking products. Access End-of-Life documents for hardware, software, and firmware release and service dates
Updated: July 24, 2026
ID: 000185734
Event code: VXR508IOV1004
This event code indicates "Too many slots provided as parameters to Assign and UnAssign Servers methods."
Updated: July 24, 2026
ID: 000011599
Event code: VXR508NIC007
This event code indicates "A configuration job already exists, Cannot create another configuration job on specified target until existing job is completed or is cancelled"
Updated: July 24, 2026
ID: 000011598
Event code: VXR508IOV124
This event code indicates "The PCIe shared adapter in slot <slot number> is not supported because the firmware version of the Chassis Infrastructure Mainboard is not the latest."
Updated: July 24, 2026
ID: 000011597
The article describes how the physical view fails to load because DNS lookups for vCenter and ESXi hosts return errors such as “Temporary failure in name resolution” or “No address associated with hostname,” caused by misconfigured DNS settings on the VxRail manager and its containers.
Updated: July 24, 2026
ID: 000194844
Event code: VXR508FAN908
This event code indicates "The Enhanced Cooling Mode feature is already disabled."
Updated: July 24, 2026
ID: 000011595
Event code: VXR508FAN907
This event code indicates "The Enhanced Cooling Mode feature is already enabled."
Updated: July 24, 2026
ID: 000011593
Event code: VXR508NIC003
This event code indicates "Missing required parameter"
Updated: July 24, 2026
ID: 000011591
Cluster reports VXR034018 or VXR034020 alarms and enablement failure. Possible causes are unreachable esrs3 servers, wrong SCG port (9443), bad credentials, or no response from Secure Remote Services.
Updated: July 24, 2026
ID: 000193409
Event code: VXR508IOV1008
This event code indicates "Invalid Virtual Adapter FQDD <FQDD value>."
Updated: July 24, 2026
ID: 000011589
iDRAC is the backend of ISM which provides hardware monitoring functionality on the VxRail appliance. This article describes the required settings on iDRAC.
Updated: July 24, 2026
ID: 000157690
Event code: VXR508FAN903
This event code indicates "Cannot enable the Enhanced Cooling Mode because an unsupported fan is inserted in the Chassis."
Updated: July 24, 2026
ID: 000011588
Event code: VXR508FAN904
This event code indicates "Cannot enable the Enhanced Cooling Mode because the Maximum Power Conservation Mode is enabled."
Updated: July 24, 2026
ID: 000011587
Event code: VXR508NIC014
This event code indicates "Invalid AttributeValue for AttributeName <attribute name>"
Updated: July 24, 2026
ID: 000011586
vCenter is showing errors for a host: "The ramdisk 'root' is full. As a result, the file * could not be written."
Updated: July 24, 2026
ID: 000193942
The 'df_service' test checks the local Service datastore available capacity on each node.
Updated: July 24, 2026
ID: 000181119
VxVerify on VxRail Manager can attempt to correct iDRAC and iSM fault by restarting iDRAC and related VxRail node services.
Updated: July 24, 2026
ID: 000205179
This article outlines the response from VxRail Engineering to the Apache Log4j Remote Code Execution Vulnerability issue known as Log4Shell. This is described in CVE-2021-44228, CVE-2021-45046, and CVE-2021-4104 (Dell article DSN-2021-007, VMware article VMSA-2021-0028)
Updated: July 24, 2026
ID: 000194410
Trying to create a disk group on an ESXi host, fails with the following error: "Failed to create multiple disk group for host XXXXX".
Updated: July 24, 2026
ID: 000192158
This article details how to confirm the build version of various VxRail components. This includes ESXi, vCenter Server Appliance, and VxRail Manager.
Updated: July 24, 2026
ID: 000189488
Event code: VXR508IOV1005
This event code indicates "Invalid slot FQDD <FQDD value>."
Updated: July 23, 2026
ID: 000011584
Event code: VXR508IOV1006
This event code indicates "Invalid PCI slot or Server slot."
Updated: July 23, 2026
ID: 000011583
Event code: VXR508NIC004
This event code indicates "Invalid parameter value for <attribute name>"
Updated: July 23, 2026
ID: 000011582
Event code: VXR508NIC022
This event code indicates "Unable to set the BIOS password because of a jumper setting on the motherboard."
Updated: July 23, 2026
ID: 000011581
Event code: VXR508IOV104
This event code indicates "The Chassis Management Controller (CMC) is unable to allocate <number of Watt> Watt for server-<server slot number> PCIe adapters."
Updated: July 23, 2026
ID: 000011580
Event code: VXR508NIC023
This event code indicates "Cannot perform the operation due to an unknown error in iDRAC."
Updated: July 23, 2026
ID: 000011579
Event code: VXR508FC003
This event code indicates "Missing required parameter."
Updated: July 23, 2026
ID: 000011574
Event code: VXR508NIC018
This event code indicates "Invalid BIOS password."
Updated: July 23, 2026
ID: 000011572