Use the following RACADM command to verify the SD feature card and its status:
racadm featurecard -s
Table 1. Status Messages Returned by featurecard -s Command
Status Message Actions
No feature card inserted. Check CMC to verify that the SD card was properly inserted. In a redundant CMC configuration, ensure that the CMC with the SD feature card installed is the active CMC and not the standby CMC.
The feature card inserted is valid and contains the following feature(s) FlexAddress: The feature card is bound to this chassis. No action required.
The feature card inserted is valid and contains the following feature(s) FlexAddress: The feature card is bound to another chassis, svctag = ABC1234, SD card SN = 01122334455 Remove the SD card; locate and install the SD card for the current chassis.
The feature card inserted is valid and contains the following feature(s) FlexAddress: The feature card is not bound to any chassis. The feature card can be moved to another chassis or can be reactivated on the current chassis. To reactivate on the current chassis, enter racadm racreset until the CMC module with the feature card installed becomes active.
Use the following RACADM command to display all activated features on the chassis:
racadm feature -s
The command returns the following status message:
Feature = FlexAddress
                                    Date Activated = 8 April 2008 - 10:39:40
                                    Feature installed from SD-card SN = 01122334455
                                 
If there are no active features on the chassis, the command returns a message:
racadm feature -s
                                    No features active on the chassis
                                 
Dell Feature Cards may contain more than one feature. Once any feature included on a Dell Feature Card has been activated on a chassis, any other features that may be included on that Dell Feature Card cannot be activated on a different chassis. In this case, the racadm feature -s command displays the following message for the affected features:
ERROR: One or more features on the SD card are active on another chassis

For more information on the feature and featurecard commands, see the Chassis Management Controller for Dell PowerEdge M1000e RACADM Command Line Reference Guide.


Évaluez ce contenu

Précis
Utile
Facile à comprendre
Avez-vous trouvé cet article utile ?
0/3000 characters
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez indiquer si l’article a été utile ou non.
  Les commentaires ne doivent pas contenir les caractères spéciaux : <>()\