Dell PowerEdge FX2 and FX2s Enclosure Owner's Manual

Daisy-chain CMC network connection

The CMC has two RJ-45 Ethernet ports, labeled Gb1 (the uplink port) and STK/Gb2 (the stacking or cable consolidation port). With basic cabling, you can connect the Gb port to the management network and leave the STK/Gb2 port unused.
CAUTION: Connecting the STK/Gb2 port to the management network will have unpredictable results if the CMC setting is not changed from default Stacking to Redundant, to implement NIC failover. In the default Stacking mode, cabling the Gb1 and STK/Gb2 ports to the same network (broadcast domain) can cause a broadcast storm. A broadcast storm can also occur if the CMC setting is changed to Redundant mode, but the cabling is daisy chained between chassis in the Stacking mode. Ensure that the cabling model matches the CMC setting for the intended usage.
NOTE: The STK/Gb2 port can also be used for CMC NIC failover. Ensure that the CMC setting is changed from default Stacking to Redundant to implement NIC failover.
If you have multiple chassis in a rack, you can reduce the number of connections to the management network by daisy-chaining up to four chassis together. This reduces the connections required from four to one.

When daisy-chaining chassis together, Gb1 is the uplink port and STK/Gb2 is the stacking (cable consolidation) port. Connect the Gb ports to the management network or to the STK port of the CMC in a chassis that is closer to the network. You must connect the STK port only to a Gb port that is further from the chain or network.

NOTE: The CMC must be installed for the system to power on. See the PowerEdge FX2/FX2s CMC User’s Guide at Dell.com/poweredgemanuals for complete instructions on setting up and operating the CMC module.
Figure 1. CMC daisy-chaining
This figure shows CMC daisy-chaining.
  1. management network
  2. CMC

Ohodnotiť tento obsah

Presné
Užitočné
Jednoducho pochopiteľné
Bol pre vás tento článok užitočný?
0/3000 characters
  Vyberte, prosím, hodnotenie (1 až 5 hviezdičiek).
  Vyberte, prosím, hodnotenie (1 až 5 hviezdičiek).
  Vyberte, prosím, hodnotenie (1 až 5 hviezdičiek).
  Vyberte, prosím, či vám článok pomohol alebo nie.
  Poznámky nemôžu obsahovať nasledujúce špeciálne znaky: <>()\