Dell PowerEdge FX2 and FX2s Enclosure Owner's Manual

Removing the bottom interposer module

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
NOTE: This is a field replaceable unit (FRU). Removal and installation procedures must be performed only by Dell certified service technicians.
NOTE: You must remove the bottom interposer module to replace a faulty module, install half-width or full-width sleds, or service other components inside the system.
  1. Ensure that you read the Safety instructions.
  2. Follow the procedure listed in Before working inside your system.
  3. Remove the following:
    • sleds
    • power supplies
    • CMC module
    • I/O module(s)
    • PCIe modules, if applicable
    • system cover
    • cooling fans
    • cooling-fan cage

Steps

  1. Turn the system over with the bottom side of the system facing up.
  2. From the bottom of the system:
    1. Remove the five screws that secure the bottom partition.
      Figure 1. Removing and installing screws securing the bottom partition
      This figure shows removing and installing screws securing the bottom partition to the system.
      1. bottom of the system
      2. screw (5)
    2. Remove the two screws that secure the bottom interposer module.
      Figure 2. Removing and installing screws securing the bottom interposer module
      This figure shows removing and installing screws securing the bottom interposer module to the system.
      1. bottom of the system
      2. screw (2)
  3. Turn the system over with the top side of the system facing up.
  4. Remove the two screws that secure the bottom partition to the top of the system.
  5. Slide the bottom partition out of the system.
    Figure 3. Removing and installing the bottom partition
    This figure shows removing and installing the bottom partition.
    1. bottom partition
    2. screw (2)
  6. Remove the two screws that secure the bottom interposer module to the top of the system.
  7. Pull out the bottom interposer module from the system.
    Figure 4. Removing and installing the bottom interposer module
    This figure shows removing and installing the bottom interposer module.
    1. bottom interposer module (2)
    2. screw (2)

Next steps

Install the bottom interposer module.

Ohodnotiť tento obsah

Presné
Užitočné
Jednoducho pochopiteľné
Bol pre vás tento článok užitočný?
0/3000 characters
  Vyberte, prosím, hodnotenie (1 až 5 hviezdičiek).
  Vyberte, prosím, hodnotenie (1 až 5 hviezdičiek).
  Vyberte, prosím, hodnotenie (1 až 5 hviezdičiek).
  Vyberte, prosím, či vám článok pomohol alebo nie.
  Poznámky nemôžu obsahovať nasledujúce špeciálne znaky: <>()\