Toshiba Solid State Drive Firmware Update

Restart required AUTO INSTALLED This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
This package contains the Toshiba KXG50PNV1T02 and KXG50PNV2T04 solid state drive firmware update. Storage firmware is a microcode that is embedded on storage devices such as hard drives or solid-state drives. The firmware manages the functionality of the devices.
To view all drivers for your XPS 15 7590, go to Drivers and downloads.
Recommended
Loading the latest available version of the driver...

This is the latest Dell validated version of this driver

This is not the latest Dell validated version of this driver

Toshiba KXG50PNV1T02_KXG50PNV2T04 5J2MJ_ZPE.exe | 3.68 MB
This is a large file. Depending on your connection speed, it may take some time to download.

File Format: ZipPack External
File Name: Toshiba KXG50PNV1T02_KXG50PNV2T04 5J2MJ_ZPE.exe
File Size: 3.68 MB
Format Description
This file contains a compressed (or zipped) set of files. Download the file to a folder on your hard drive, and then run (double-click) it to unzip the set of files. Follow the instructions to complete the installation.
To ensure the integrity of your download, please verify the checksum value.
MD5:
c500bedf305b88ba427ecac052f1766a
SHA1:
a8eb502e9c4e9842916c307611fb3c229ece35b1
SHA-256:
e2b12a0eaecf4f6bd96e6fe396e82c51ff3220616260d51ff09e3dba86e001da

Find more updates. Use SupportAssist to find all the latest driver updates for your device.

Fixes & Enhancements

Fixes:
- Fixed the issue where a Windows error message is displayed when the drive is not detected.

Enhancements:
- Improved the performance of the solid state drive (SSD).
Read More

Version

AFDA4105, A00

Release date

01 Aug 2019

Download Type

Firmware

Category

Storage

Importance

Recommended
Dell Technologies recommends applying this update during your next scheduled update cycle. The update contains changes to maintain overall system health. It ensures that the system software remains current and compatible with other system modules (firmware, BIOS, drivers, and software) and may include other new features.

Additional details

Show All | Hide All
You must backup all the important files before performing this update. If the firmware process is interrupted for any reason, your solid state drive may not function properly.
Windows 7, 32-bit
Windows 7, 64-bit
Windows 8, 32-bit
Windows 8, 64-bit
Windows 8.1, 32-bit
Windows 8.1, 64-bit
Windows 10, 32-bit
Windows 10, 64-bit
TOSHIBA XG5 2TB PCIE NVME 2280 SSD (CLASS 40)
TOSHIBA XG5-P 1TB PCIE NVME 2280 HIGH PERFORMANCE SSD (CLASS 50)
Firmware upgrade through the Windows utility

Procedure
1. Run the utility to start the firmware update process.
2. On the first screen, if the target SSD is not listed, select it and then click Update.
The next screen is a warning message. It states the risks and reminds user to back up important files before proceeding.
3. Click OK to proceed.
Firmware upgrade proceeds. When the firmware upgrade process completes, you are prompted to reboot the system.
4. Close all open applications, and save your work before rebooting the system.
The system reboots and loads the firmware. Once the firmware update is complete, a message saying the firmware update done is displayed.
5. Sign in to the operating system.
6. To confirm that the firmware update was successful, open Device manager > open SSD> click Properties> choose hardware ID under Details and check the firmware version.

Drivers help and tutorials