RFCache source configuration is not consistent

This article applies to   This article does not apply to 

Symptoms



Issue Description

 RFCache warning that the source configuration is not consistent.

Scenario

An alert in the ScaleIO GUI warning the user that RFCache source configuration is not consistent due to a SDS device being in an errored state.

Symptoms

Screenshot from the ScaleIO GUI showing the RFCache warning and the SDS device in an errored state.
kA23a000000GHppCAG_3_0

Impact

There is no impact to the overall cluster.

Cause

Root Cause

RFCache receives a list of SDS devices to cache for. In this case, one of the configured SDS devices was unable to serve IO and therefore RFCache was unable to read from it. RFCache reported this as an inconsistent configuration.

Resolution

Workaround

Remove the data disk from the storage pool that is in an errored state and clear the RFCache error.

Additional Information

Impacted Versions

2.x

Fixed In Version

3.x

Affected Products

PowerFlex Software

Products

PowerFlex Software, VxFlex Product Family