Connectrix MDS: Module X reported warning fcX/21-64due to Test Failed, Could not identify the Faulty Device in device DEV_UNDEF

Summary: SnakeLoobpack passed incorrect port range to module warning when SnakeLoopback could not identify faulty device.

This article applies to   This article does not apply to 

Symptoms



SnakeLoobpack passed incorrect port range to module warning when SnakeLoopback could not identify faulty device.
Module failed to pass diagnostics.

'show logging logfile'
2017 Apr  2 01:18:30 switchname %DIAG_PORT_LB-2-SNAKE_TEST_LOOPBACK_TEST_FAIL: Module:8 Test:SnakeLoopback failed 10 consecutive times. Faulty module: affected ports:1-40,45-48  Error:Test Failed, Could not identify the Faulty Device 

2017 Apr  2 01:18:30 switchname %MODULE-4-MOD_WARNING: Module 8 (Serial number: JAE20xxxxxx) reported warning fc8/21-64due to Test Failed, Could not identify the Faulty Device in device DEV_UNDEF (device error 0xc0000300)

'show module'
<snip>
Mod  Online Diag Status
---  ------------------
8    Fail



Module 8 has 48 interfaces, however the module warning is for up to 64 interfaces.

8    48     2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9     ok

When diagnostics cannot identify the faulty device it will report it as "device DEV_UNDEF".

Resolution

Error is cosmetic and does no impact to FC traffic.

Permanent fix:
Upgrade to NX-OS 8.1(1) and above.

Affected Products

Connectrix MDS-9710

Products

Connectrix, Connectrix MDS-9706, Connectrix MDS-9706-V2, Connectrix MDS-9710, Connectrix MDS-9710-V2, Connectrix MDS-9718, Connectrix MDS-Series Firmware, Connectrix MDS-Series Firmware 6.X, Connectrix MDS-Series Firmware 7.X