Avamar: VM Image Backups fail with code 10014
Summary: VM image backups fail with code 10014 due to a corrupted reference backup taken at an earlier date
Αυτό το άρθρο ισχύει για
Αυτό το άρθρο δεν ισχύει για
Αυτό το άρθρο δεν συνδέεται με κάποιο συγκεκριμένο προϊόν.
Δεν προσδιορίζονται όλες οι εκδόσεις προϊόντων σε αυτό το άρθρο.
Symptoms
The logs showed the error as below:
>2020-03-23 08:29:40 avvcbimage Info <14698>: submitting pax container change block extents: >2020-03-23 08:29:40 avvcbimage Error <0000>: [IMG0010] pax_container::beginfile(virtdisk-flat.vmdk) returned problem:32 >2020-03-23 08:29:40 avvcbimage Info <9772>: Starting graceful (staged) termination, openPaxFile returned error (wrap-up stage) >2020-03-23 08:29:40 avvcbimage Error <0000>: [IMG1003] Backup of [AVAMAR_AVAMAR_AVAMAR_AVAMAR_ AVAMAR-12] AVAMAR01 (347ca96a-ccc7-497a-bded-a66fab5f986f)/AVAMAR01 (347ca96a-ccc7-497a-bded-a66fab5f986f)_2.vmdk failed >2020-03-23 08:29:40 avvcbimage Info <16041>: VDDK:VixDiskLib: VixDiskLib_Close: Close disk. >2020-03-23 08:30:27 avvcbimage Info <6033>: Begin STDERR from run-at-end: curl: (35) error:140770FC:SSL routines:SSL23_GET_SERVER_HELLO:unknown protocol Use of uninitialized value $availableversion in concatenation (.) or string at /usr/local/avamarclient/etc/scripts/proxymountclient.pl line 284. After further investigation found the problem with labelnum taken from previous backup that is corrupted and causing the failure:
2020-03-27 10:30:41 avvcbimage Info <11986>: Changed block tracking is engaged for this VM 2020-03-27 10:30:41 avvcbimage Info <11987>: Reference backup is #713 captured on 2020-02-29 23:34:26 2020-03-27 10:30:41 avvcbimage Info <14680>: A reference to a valid prior backup is available so this will be an incremental.
Cause
A corrupted reference backup number causing the backup to fail.
Resolution
A workaround to fix the issue:
- Disable CBT and take a full backup.
- Enable CBT again to validate that incremental backup is also working fine.