PPDM: I backup NAS hanno esito negativo con errore "Failed to parse the Override Append Path" e "Exception occurred while parsing the chunk metadata information"

Summary: I backup NAS di PowerProtect Data Manager hanno esito negativo con l'errore "Failed to parse the Override Append Path" e l'avvertenza "Exception occurred while parsing the chunk metadata information". ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

I seguenti messaggi vengono visualizzati nei registri dei processi di asset esportati per i backup NAS di PowerProtect Data Manager:
2024-05-03T03:50:38.763Z [TRACE_ID:9b50d18fdf9f2df3;JOB_ID:b607f52ee1def511;TASK_ID:996d7debf831a7cd]3  (pid59) PowerProtect Data Manager error Failed to parse the Override Append Path.

2024-05-3T03:50:49.901Z [TRACE_ID_9b50d18fdf9f2df3_JOB_ID_b607f52ee1def511_TASK_ID_996d7debf831a7cd]3  1921518784 88 0 ddfssv PowerProtect Data Manager warning Exception occurred while parsing the chunk metadata information.

Cause

Quando Override Append Path è vuoto, vengono visualizzati i messaggi di errore e di avvertenza.

L'opzione Override Append Path viene impostata solo quando un utente desidera ripristinare i file in un'altra posizione del percorso originale.

Resolution

Si tratta di un problema noto risolto in PowerProtect Data Manager 19.17.
Article Properties
Article Number: 000227387
Article Type: Solution
Last Modified: 31 July 2024
Version:  1