Os nós do PowerScale são lidos somente após o upgrade do OneFS 9.1

Summary: Depois de fazer upgrade de um cluster para o OneFS 9.1.0.20, todos os nós do PowerScale (F200, F600, F900) no cluster entrarão no modo Somente leitura.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Depois de fazer upgrade de um cluster para o OneFS 9.1.0.20, "isi status" mostra todos os nós do PowerScale no modo somente leitura (RO):
 
Node Pool Name: f600_60tb-ssd_384gb               Protection:        +2d:1n
Pool Storage:     HDD                 SSD Storage    
Size:             0 (0 Raw)           0 (0 Raw)      
VHS Size:         0.0                 
Used:             0 (n/a)             0 (n/a)        
Avail:            0 (n/a)             0 (n/a)        

                           Throughput (bps)  HDD Storage      SSD Storage
Name               Health|  In   Out  Total| Used / Size     |Used / Size
-------------------+-----+-----+-----+-----+-----------------+-----------------
123|n/a            |-A-R |938.7| 9.9M| 9.9M|(No Storage HDDs)|(No Storage SSDs)
124|n/a            |-A-R |    0| 9.9M| 9.9M|(No Storage HDDs)|(No Storage SSDs)
125|n/a            |-A-R |    0|10.8M|10.8M|(No Storage HDDs)|(No Storage SSDs)
126|n/a            |-A-R |    0| 9.9M| 9.9M|(No Storage HDDs)|(No Storage SSDs)
127|n/a            |-A-R | 1.4k| 9.9M| 9.9M|(No Storage HDDs)|(No Storage SSDs)
128|n/a            |-A-R |    0| 7.9M| 7.9M|(No Storage HDDs)|(No Storage SSDs)
129|n/a            |-A-R |    0| 7.9M| 7.9M|(No Storage HDDs)|(No Storage SSDs)
130|n/a            |-A-R |    0| 7.3M| 7.3M|(No Storage HDDs)|(No Storage SSDs)
-------------------+-----+-----+-----+-----+-----------------+-----------------
f600_60tb-ssd_384gb|  OK |293.3| 9.2M| 9.2M|(No Storage HDDs)|(No Storage SSDs)



Você verá entradas semelhantes às seguintes no arquivo /var/log/messages para os nós afetados:
 
2022-07-26T01:40:46+02:00  (id92) isi_testjournal: NVDIMM is persistent
2022-07-26T01:40:46+02:00  (id92) isi_testjournal: NVDIMM armed for persistent writes
2022-07-26T01:40:47+02:00  (id92) ifconfig: Configure: /sbin/ifconfig ue0 netmask 255.255.255.0 169.254.0.40
2022-07-26T01:40:47+02:00  (id92) dsm_ism_srvmgrd[2056]: ISM0000 [iSM@674.10892.2 EventID="8716" EventCategory="Audit" EventSeverity="info" IsPastEvent="false" language="en-US"] The iDRAC Service Module is started on the operating system (OS) of server.
2022-07-26T01:40:47+02:00  (id92) dsm_ism_srvmgrd[2056]: ISM0003 [iSM@674.10892.2 EventID="8196" EventCategory="Audit" EventSeverity="error" IsPastEvent="false" language="en-US"] The iDRAC Service Module is unable to discover iDRAC from the operating system of the server.
2022-07-26T01:44:15+02:00  (id92) isi_testjournal: PowerTools Agent Query Exception: Timeout (20 sec) exceeded for request http://127.0.0.1:8086/api/PT/v1/host/sensordata?sensorSelector=iDRAC.Embedded.1%23SystemBoardNVDIMMBattery&sensorType=DellSensor data: HTTPConnectionPool(host='127.0.0.1', port=8086): Read timed out. (read timeout=20)
2022-07-26T01:44:20+02:00  (id92) isi_testjournal: Query to PowerTools Agent for NVDIMM Battery failed

Cause

O problema parece estar relacionado às alterações no código de monitoramento de status do NVDIMM feitas no OneFS versão 9.1.0.19, o que pode fazer com que ocorra um timeout durante a consulta inicial de status do NVDIMM na inicialização, colocando o nó no modo somente leitura. Mesmo que as consultas subsequentes de status sejam bem-sucedidas, o nó não retorna automaticamente ao modo De leitura e gravação. O OneFS 9.2.x e os mais recentes não são afetados por esse problema.

Resolution

Para verificar se o NVDIMM está íntegro e se você está executando o problema descrito neste artigo da KB, execute os quatro comandos a seguir:
 

# isi_hwmon -b NVDIMMHealthMonitoring
# isi_hwmon -b NVDIMMPersistence
# /opt/dell/DellPTAgent/tools/pta_call get agent/info
# /opt/dell/DellPTAgent/tools/pta_call post "host/sensordata?sensorSelector=iDRAC.Embedded.1%23SystemBoardNVDIMMBattery&sensorType=DellSensor"


 

Esses comandos são apenas comandos de consulta e devem ser considerados não disruptivos.

O resultado dos comandos para um nó nesse estado deve ser semelhante a:
 

# isi_hwmon -b NVDIMMHealthMonitoring
DIMM SLOT A7: OK

# isi_hwmon -b NVDIMMPersistence
NVDIMM Index 0

                       State: PERSISTENT
            Vendor Serial ID: xxxxxxxxx
       Correctable ECC Count: 0     
     Uncorrectable ECC Count: 0
                Current Temp: 255
                      Health: 0
                NVM Lifetime: 90
    Warning Threshold Status: 0
      Error Threshold Status: 0
          Health Info Status: 0
        Critical Health Info: 0
        Critical Info Status: 0
            Last Save Status: 0
         Last Restore Status: 0
           Last Flush Status: 0
                       Armed: 1
SMART/Health Events Observed: 0
        FW Health Monitoring: 1
               NVDIMM Mapped: 1

# /opt/dell/DellPTAgent/tools/pta_call post "host/sensordata?sensorSelector=iDRAC.Embedded.1%23SystemBoardNVDIMMBattery&sensorType=DellSensor"
Request sent to DellPTAgent @ http://127.0.0.1:8086 [127.0.0.1]
{
    "HealthState": "OK",
    "EnabledState": "Enabled",
    "ElementName": "System Board NVDIMM Battery",
    "SensorType": "Other",
    "Id": "iDRAC.Embedded.1_0x23_SystemBoardNVDIMMBattery",
    "CurrentState": "Good"
}
Response: status: 200 [OK], size: 223 bytes, latency: 0.034 seconds.

# /opt/dell/DellPTAgent/tools/pta_call get agent/info
Request sent to DellPTAgent @ http://127.0.0.1:8086 [127.0.0.1]
{
    "idrac_ethernet_ip": "0.0.0.0",
    "servicetag": "xxxxx",
    "uptime": "2511 seconds ( 41 minutes 51 seconds )",
    "status": {
        "agent": "OK",
        "idracConnection": "OK",
        "idraccache": "OK",
        "iSM": "N/A"
    },
    "name": "ClusterName-123",
    "MarvellLibraryVersion": "Not loaded",
   "system_uuid": "xxxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx",
    "default_server_cert": "true",
    "rest_endpoints": "http://127.0.0.1:8086"" [127.0.0.1],
    "ptagentversion": "2.5.6-4",
    "domain": "",
    "host_epoch_time": "xxxxxxxxxx.354221 (secs.usecs)",
    "os_version": "9.1.0.0",
    "mfr": "Dell Inc.",
    "process_id": "2071",
    "api_blocking_enabled": "false",
    "host_pass_thru_ip": "xxx.xxx.xxx.xxx",
    "model": "PowerScale F600",
    "idrac_pass_thru_ip": "xxx.xxx.xxx.xxx",
    "os": "Isilon OneFS",
    "ism_version": "dell-dcism-3.4.6.13_7"
}
Response: status: 200 [OK], size: 871 bytes, latency: 0.009 seconds.


 

O resultado aqui é um exemplo, e pode haver variações na saída que você obtém. A parte importante é que o resultado é semelhante e que você não receba uma mensagem de erro em vez do resultado.

- Se houver indicações de problemas/erros de comunicação, você deverá continuar solucionando o problema, envolvendo um HW L2/SME e/ou a equipe de suporte do PowerEdge, conforme necessário. 

- Se o resultado indicar que o NVDIMM está em um estado bom e não há problemas, você pode limpar manualmente o estado ro usando o seguinte comando:

# /usr/bin/isi_hwtools/isi_read_only --unset=system-nvdimm-failed


Depois de aplicar a etapa corretiva, monitore o nó por cerca de 10 minutos para garantir que ele não volte para o modo RO. Se o nó for reiniciado ou religado, esse problema poderá ocorrer novamente, e essa solução temporária pode precisar ser reaplicada. A engenharia do PowerScale está ciente desse problema e está investigando as etapas de redução a serem implementadas em uma próxima versão do OneFS 9.1. Enquanto isso, para resolver permanentemente esse problema, você pode fazer upgrade do cluster para o OneFS 9.2 ou mais recente.

Affected Products

PowerScale F200, PowerScale F600, PowerScale F900
Article Properties
Article Number: 000201933
Article Type: Solution
Last Modified: 06 Jul 2023
Version:  3
Find answers to your questions from other Dell users