Symptoms
Node Pool Name: f600_60tb-ssd_384gb Protection: +2d:1n Pool Storage: HDD SSD Storage Size: 0 (0 Raw) 0 (0 Raw) VHS Size: 0.0 Used: 0 (n/a) 0 (n/a) Avail: 0 (n/a) 0 (n/a) Throughput (bps) HDD Storage SSD Storage Name Health| In Out Total| Used / Size |Used / Size -------------------+-----+-----+-----+-----+-----------------+----------------- 123|n/a |-A-R |938.7| 9.9M| 9.9M|(No Storage HDDs)|(No Storage SSDs) 124|n/a |-A-R | 0| 9.9M| 9.9M|(No Storage HDDs)|(No Storage SSDs) 125|n/a |-A-R | 0|10.8M|10.8M|(No Storage HDDs)|(No Storage SSDs) 126|n/a |-A-R | 0| 9.9M| 9.9M|(No Storage HDDs)|(No Storage SSDs) 127|n/a |-A-R | 1.4k| 9.9M| 9.9M|(No Storage HDDs)|(No Storage SSDs) 128|n/a |-A-R | 0| 7.9M| 7.9M|(No Storage HDDs)|(No Storage SSDs) 129|n/a |-A-R | 0| 7.9M| 7.9M|(No Storage HDDs)|(No Storage SSDs) 130|n/a |-A-R | 0| 7.3M| 7.3M|(No Storage HDDs)|(No Storage SSDs) -------------------+-----+-----+-----+-----+-----------------+----------------- f600_60tb-ssd_384gb| OK |293.3| 9.2M| 9.2M|(No Storage HDDs)|(No Storage SSDs)
Etkilenen düğümler için /var/log/messages dosyasında aşağıdakine benzer girişler görürsünüz:
2022-07-26T01:40:46+02:00 (id92) isi_testjournal: NVDIMM is persistent 2022-07-26T01:40:46+02:00 (id92) isi_testjournal: NVDIMM armed for persistent writes 2022-07-26T01:40:47+02:00 (id92) ifconfig: Configure: /sbin/ifconfig ue0 netmask 255.255.255.0 169.254.0.40 2022-07-26T01:40:47+02:00 (id92) dsm_ism_srvmgrd[2056]: ISM0000 [iSM@674.10892.2 EventID="8716" EventCategory="Audit" EventSeverity="info" IsPastEvent="false" language="en-US"] The iDRAC Service Module is started on the operating system (OS) of server. 2022-07-26T01:40:47+02:00 (id92) dsm_ism_srvmgrd[2056]: ISM0003 [iSM@674.10892.2 EventID="8196" EventCategory="Audit" EventSeverity="error" IsPastEvent="false" language="en-US"] The iDRAC Service Module is unable to discover iDRAC from the operating system of the server. 2022-07-26T01:44:15+02:00 (id92) isi_testjournal: PowerTools Agent Query Exception: Timeout (20 sec) exceeded for request http://127.0.0.1:8086/api/PT/v1/host/sensordata?sensorSelector=iDRAC.Embedded.1%23SystemBoardNVDIMMBattery&sensorType=DellSensor data: HTTPConnectionPool(host='127.0.0.1', port=8086): Read timed out. (read timeout=20) 2022-07-26T01:44:20+02:00 (id92) isi_testjournal: Query to PowerTools Agent for NVDIMM Battery failed
Cause
Resolution
NVDIMM'in iyi durumda olduğunu ve bu KB'de açıklanan sorunla karşı karşıdan çıktıyı doğrulamak için aşağıdaki dört komutu çalıştırın:
# isi_hwmon -b NVDIMMHealthMonitoring # isi_hwmon -b NVDIMMPersistence # /opt/dell/DellPTAgent/tools/pta_call get agent/info # /opt/dell/DellPTAgent/tools/pta_call post "host/sensordata?sensorSelector=iDRAC.Embedded.1%23SystemBoardNVDIMMBattery&sensorType=DellSensor"
Bu komutlar yalnızca sorgu komutlarıdır ve kesintisiz olarak düşünülmelidir.
Bu durumdaki bir düğümün komutlarının çıktısı aşağıdakilere benzer olmalıdır:
# isi_hwmon -b NVDIMMHealthMonitoring
DIMM SLOT A7: OK
# isi_hwmon -b NVDIMMPersistence
NVDIMM Index 0
State: PERSISTENT
Vendor Serial ID: xxxxxxxxx
Correctable ECC Count: 0
Uncorrectable ECC Count: 0
Current Temp: 255
Health: 0
NVM Lifetime: 90
Warning Threshold Status: 0
Error Threshold Status: 0
Health Info Status: 0
Critical Health Info: 0
Critical Info Status: 0
Last Save Status: 0
Last Restore Status: 0
Last Flush Status: 0
Armed: 1
SMART/Health Events Observed: 0
FW Health Monitoring: 1
NVDIMM Mapped: 1
# /opt/dell/DellPTAgent/tools/pta_call post "host/sensordata?sensorSelector=iDRAC.Embedded.1%23SystemBoardNVDIMMBattery&sensorType=DellSensor"
Request sent to DellPTAgent @ http://127.0.0.1:8086 [127.0.0.1]
{
"HealthState": "OK",
"EnabledState": "Enabled",
"ElementName": "System Board NVDIMM Battery",
"SensorType": "Other",
"Id": "iDRAC.Embedded.1_0x23_SystemBoardNVDIMMBattery",
"CurrentState": "Good"
}
Response: status: 200 [OK], size: 223 bytes, latency: 0.034 seconds.
# /opt/dell/DellPTAgent/tools/pta_call get agent/info
Request sent to DellPTAgent @ http://127.0.0.1:8086 [127.0.0.1]
{
"idrac_ethernet_ip": "0.0.0.0",
"servicetag": "xxxxx",
"uptime": "2511 seconds ( 41 minutes 51 seconds )",
"status": {
"agent": "OK",
"idracConnection": "OK",
"idraccache": "OK",
"iSM": "N/A"
},
"name": "ClusterName-123",
"MarvellLibraryVersion": "Not loaded",
"system_uuid": "xxxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx",
"default_server_cert": "true",
"rest_endpoints": "http://127.0.0.1:8086"" [127.0.0.1],
"ptagentversion": "2.5.6-4",
"domain": "",
"host_epoch_time": "xxxxxxxxxx.354221 (secs.usecs)",
"os_version": "9.1.0.0",
"mfr": "Dell Inc.",
"process_id": "2071",
"api_blocking_enabled": "false",
"host_pass_thru_ip": "xxx.xxx.xxx.xxx",
"model": "PowerScale F600",
"idrac_pass_thru_ip": "xxx.xxx.xxx.xxx",
"os": "Isilon OneFS",
"ism_version": "dell-dcism-3.4.6.13_7"
}
Response: status: 200 [OK], size: 871 bytes, latency: 0.009 seconds.
Burada verilen çıktı bir örnektir ve elde ettiyseniz çıktıda farklılık olabilir. Önemli olan, çıktının benzer görünüyor ve çıktı yerine bir hata mesajı alamayabileceğinizdir.
- İletişim sorunları/hataları belirtisi varsa HW L2/SME ve/veya PowerEdge destek ekibini gerektiği gibi kullanarak sorunu gidermeye devam edin.
- Çıktı, NVDIMM'nin iyi durumda olduğunu ve herhangi bir sorun olmadığını gösterirse aşağıdaki komutu kullanarak RO durumunu manuel olarak temizleyebilirsiniz:
# /usr/bin/isi_hwtools/isi_read_only --unset=system-nvdimm-failed
Düzeltici adımı uygulandıktan sonra, ro moduna geri açılmay olduğundan emin olmak için düğümü yaklaşık 10 dakika boyunca izleyin. Düğüm kapatıldıysa veya yeniden başlatıldıysa bu sorun tekrar ortaya çıkabilir ve bu geçici çözümün yeniden geçerli olması gerekebilir. PowerScale Mühendislik ekibi bu sorunun farkındadır ve yaklaşan OneFS 9.1 sürümünde uygulanacak risk azaltma adımlarını araştırmayı hedeflemektedir. Bu sırada bu sorunu kalıcı olarak çözmek için kümeyi OneFS 9.2 veya daha yeni bir sürüme yükseltin.