Uzly PowerScale po upgradu OneFS 9.1 přejdou pouze ke čtení
Summary: Po upgradu clusteru na systém OneFS 9.1.0.20 všechny uzly PowerScale (F200, F600, F900) v clusteru přejdou do režimu pouze pro čtení.
Symptoms
Node Pool Name: f600_60tb-ssd_384gb Protection: +2d:1n Pool Storage: HDD SSD Storage Size: 0 (0 Raw) 0 (0 Raw) VHS Size: 0.0 Used: 0 (n/a) 0 (n/a) Avail: 0 (n/a) 0 (n/a) Throughput (bps) HDD Storage SSD Storage Name Health| In Out Total| Used / Size |Used / Size -------------------+-----+-----+-----+-----+-----------------+----------------- 123|n/a |-A-R |938.7| 9.9M| 9.9M|(No Storage HDDs)|(No Storage SSDs) 124|n/a |-A-R | 0| 9.9M| 9.9M|(No Storage HDDs)|(No Storage SSDs) 125|n/a |-A-R | 0|10.8M|10.8M|(No Storage HDDs)|(No Storage SSDs) 126|n/a |-A-R | 0| 9.9M| 9.9M|(No Storage HDDs)|(No Storage SSDs) 127|n/a |-A-R | 1.4k| 9.9M| 9.9M|(No Storage HDDs)|(No Storage SSDs) 128|n/a |-A-R | 0| 7.9M| 7.9M|(No Storage HDDs)|(No Storage SSDs) 129|n/a |-A-R | 0| 7.9M| 7.9M|(No Storage HDDs)|(No Storage SSDs) 130|n/a |-A-R | 0| 7.3M| 7.3M|(No Storage HDDs)|(No Storage SSDs) -------------------+-----+-----+-----+-----+-----------------+----------------- f600_60tb-ssd_384gb| OK |293.3| 9.2M| 9.2M|(No Storage HDDs)|(No Storage SSDs)
V souboru /var/log/messages se u dotčených uzlů zobrazí položky podobné následujícím:
2022-07-26T01:40:46+02:00 (id92) isi_testjournal: NVDIMM is persistent 2022-07-26T01:40:46+02:00 (id92) isi_testjournal: NVDIMM armed for persistent writes 2022-07-26T01:40:47+02:00 (id92) ifconfig: Configure: /sbin/ifconfig ue0 netmask 255.255.255.0 169.254.0.40 2022-07-26T01:40:47+02:00 (id92) dsm_ism_srvmgrd[2056]: ISM0000 [iSM@674.10892.2 EventID="8716" EventCategory="Audit" EventSeverity="info" IsPastEvent="false" language="en-US"] The iDRAC Service Module is started on the operating system (OS) of server. 2022-07-26T01:40:47+02:00 (id92) dsm_ism_srvmgrd[2056]: ISM0003 [iSM@674.10892.2 EventID="8196" EventCategory="Audit" EventSeverity="error" IsPastEvent="false" language="en-US"] The iDRAC Service Module is unable to discover iDRAC from the operating system of the server. 2022-07-26T01:44:15+02:00 (id92) isi_testjournal: PowerTools Agent Query Exception: Timeout (20 sec) exceeded for request http://127.0.0.1:8086/api/PT/v1/host/sensordata?sensorSelector=iDRAC.Embedded.1%23SystemBoardNVDIMMBattery&sensorType=DellSensor data: HTTPConnectionPool(host='127.0.0.1', port=8086): Read timed out. (read timeout=20) 2022-07-26T01:44:20+02:00 (id92) isi_testjournal: Query to PowerTools Agent for NVDIMM Battery failed
Cause
Resolution
Chcete-li ověřit, zda je paměť NVDIMM v dobrém stavu a že dochází k problému popsanému v tomto článku znalostí, spusťte následující čtyři příkazy:
# isi_hwmon -b NVDIMMHealthMonitoring # isi_hwmon -b NVDIMMPersistence # /opt/dell/DellPTAgent/tools/pta_call get agent/info # /opt/dell/DellPTAgent/tools/pta_call post "host/sensordata?sensorSelector=iDRAC.Embedded.1%23SystemBoardNVDIMMBattery&sensorType=DellSensor"
Tyto příkazy jsou pouze příkazy dotazu a měly by být považovány za nezrušitelné.
Výstup příkazů pro uzel v tomto stavu by měl být podobný:
# isi_hwmon -b NVDIMMHealthMonitoring
DIMM SLOT A7: OK
# isi_hwmon -b NVDIMMPersistence
NVDIMM Index 0
State: PERSISTENT
Vendor Serial ID: xxxxxxxxx
Correctable ECC Count: 0
Uncorrectable ECC Count: 0
Current Temp: 255
Health: 0
NVM Lifetime: 90
Warning Threshold Status: 0
Error Threshold Status: 0
Health Info Status: 0
Critical Health Info: 0
Critical Info Status: 0
Last Save Status: 0
Last Restore Status: 0
Last Flush Status: 0
Armed: 1
SMART/Health Events Observed: 0
FW Health Monitoring: 1
NVDIMM Mapped: 1
# /opt/dell/DellPTAgent/tools/pta_call post "host/sensordata?sensorSelector=iDRAC.Embedded.1%23SystemBoardNVDIMMBattery&sensorType=DellSensor"
Request sent to DellPTAgent @ http://127.0.0.1:8086 [127.0.0.1]
{
"HealthState": "OK",
"EnabledState": "Enabled",
"ElementName": "System Board NVDIMM Battery",
"SensorType": "Other",
"Id": "iDRAC.Embedded.1_0x23_SystemBoardNVDIMMBattery",
"CurrentState": "Good"
}
Response: status: 200 [OK], size: 223 bytes, latency: 0.034 seconds.
# /opt/dell/DellPTAgent/tools/pta_call get agent/info
Request sent to DellPTAgent @ http://127.0.0.1:8086 [127.0.0.1]
{
"idrac_ethernet_ip": "0.0.0.0",
"servicetag": "xxxxx",
"uptime": "2511 seconds ( 41 minutes 51 seconds )",
"status": {
"agent": "OK",
"idracConnection": "OK",
"idraccache": "OK",
"iSM": "N/A"
},
"name": "ClusterName-123",
"MarvellLibraryVersion": "Not loaded",
"system_uuid": "xxxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx",
"default_server_cert": "true",
"rest_endpoints": "http://127.0.0.1:8086"" [127.0.0.1],
"ptagentversion": "2.5.6-4",
"domain": "",
"host_epoch_time": "xxxxxxxxxx.354221 (secs.usecs)",
"os_version": "9.1.0.0",
"mfr": "Dell Inc.",
"process_id": "2071",
"api_blocking_enabled": "false",
"host_pass_thru_ip": "xxx.xxx.xxx.xxx",
"model": "PowerScale F600",
"idrac_pass_thru_ip": "xxx.xxx.xxx.xxx",
"os": "Isilon OneFS",
"ism_version": "dell-dcism-3.4.6.13_7"
}
Response: status: 200 [OK], size: 871 bytes, latency: 0.009 seconds.
Příklad je uveden ve výstupu a ve výstupu může být rozdíl. Důležitou součástí je, že výstup vypadá podobně a že místo výstupu se nezobrazí chybová zpráva.
– Pokud narazíte na jakékoli známky problémů/chyb komunikace, musíte pokračovat v odstraňování problému, podle potřeby zapojení hardwarového L2/SME nebo týmu podpory PowerEdge.
– Pokud výstup signalizuje, že je paměť NVDIMM v dobrém stavu a nedochází k žádným problémům, můžete ručně vymazat stav RO pomocí následujícího příkazu:
# /usr/bin/isi_hwtools/isi_read_only --unset=system-nvdimm-failed
Po provedení opravného kroku sledujte uzel přibližně 10 minut, abyste se ujistili, že se nedaří vrátit do režimu RO. Pokud se uzel vypíná nebo restartuje, k tomuto problému může dojít znovu a může být nutné znovu použít toto náhradní řešení. Technický tým PowerScale si je tohoto problému vědom a zkoumá kroky pro zmírnění rizik, které je třeba zavést v nadcházející verzi OneFS 9.1. Mezitím můžete tento problém trvale vyřešit upgradem na systém OneFS 9.2 nebo novější.