GDDR: Tape Profile validation fails with RC8 and error message Error Message GDDT022E

Summary: Tape Profile validation fails with RC=8 and error message: When REPL_STATUS reports status as REPL_SLOW instead of SUCCESS.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Script processing is delayed until the DLm replication for the selected Tenant reaches full synchronization. This delays the customers processing.

Tape Profile validation fails with RC=8 and error message:
GDDT022E GD14 Profile IPPFPS is not replicated to DC3 as expected - not processed
When REPL_STATUS reports its status as REPL_SLOW instead of SUCCESS. This prevents scripts from running until the DLm replication for the selected Tenant reaches full synchronization.

Cause

Once a REPL_SLOW condition is present, Tape Profile Validation for this tenant should issue a warning message for the REPL_SLOW condition and end with RC=4 (allow script to run) instead of RC=8 (fail script).

Resolution

Workaround:

  • Wait until synchronization.is complete before processing any scripts.


Permanent Fix:

  • For GDDR 6.0, PTF GD60017 has been developed to correct the issue. It is available to download from Dell Technologies Online Support.
  • For GDDR 5.3, PTF GD53106 has been developed to correct the issue. It is available to download from Dell Technologies Online Support.

Affected Products

Geographically Dispersed Disaster Restart (GDDR)
Article Properties
Article Number: 000213680
Article Type: Solution
Last Modified: 06 Mar 2025
Version:  3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.