MFE zDP:QUERY 命令的 RC 不正確。推出新訊息 EIP0287W/E

Summary: QUERY 命令的 RC 不正確

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

當 TGT 中的其中一個 PowerMax 系統離線時,「QUERY TGT」、STATUS、DEVICE 命令會傳回 RC=0。   
  
當 VDG 包含已從 PowerMax 系統刪除的裝置時,QUERY VDG 命令會傳回 RC=0。    

已更新 zDP 定義公用程式,以根據MAX_RC和警告/錯誤訊息嚴重性設定最終返回代碼。
                                               
如果 PowerMax 系統上沒有裝置,則 QUERY 輸出中的裝置專案會標示為「*」。      
A new message will also be issued:                           
EIP0287W/E VDG , SYMM , some devices were not found on the controller 

Cause

這是因為軟體問題所導致。

Resolution

永久修正方法: 
  • 針對 Mainframe Enablers 8.5,已開發 PTF SF85107 來修正問題。可從 Dell 線上支援下載。

Additional Information

PTF 主機殼蓋注意事項: 
 
++PTF(SF85107) REWORK(2021333) .                               
++VER(Z038) FMID(SSCF850)                                      
      PRE(                                                     
          SF85068 SF85084                                       
          )                                                    
   /*                                                          
*------------------------------------------------------------- 
* PROBLEM DESCRIPTION(S):                                       
* ------------------------------------------------------------ 
* PROBLEM FIXED: OPT 590911 585747                             
* USERS AFFECTED: zDP users                                    
* PROBLEM DESCRIPTION: Incorrect RC for the QUERY command      
* DESCRIPTION DETAIL:                                          
*                                                              
* The QUERY TGT,STATUS,DEVICE command returns RC=0 when one    
* of the PowerMax systems in TGT is offline.                    
* The QUERY VDG command returns RC=0 when the VDG contains     
* devices that have been deleted from the PowerMax system.     
*                                                              
* PROBLEM RESOLUTION:                                           
*                                                              
* zDP Definition Utility has been updated to set final return  
* code based on the MAX_RC and the warning/error message       
* severity.                                                     
* If a device doesn't exist on a PowerMax system, the device   
* entry in the QUERY output will be marked with a '*'.         
* A new message will also be issued:                           
* EIP0287W/E VDG , SYMM , some       
* devices were not found on the controller                     
*                                                               
*                                                              
* MODULES: EIPINIT                                             
*          EIPMTBL                                             
*                                                               
* ------------------------------------------------------------ 
* SF85107 29 Nov 2021 12:03:35                                 
* ------------------------------------------------------------ 
*  OPT Summary                                                  
*  The following OPTs were addressed by this PTF:              
*                                                              
*    585747  590911                                            
*                                                               
*------------------------------------------------------------- 

Affected Products

Mainframe Enablers
Article Properties
Article Number: 000196303
Article Type: Solution
Last Modified: 22 Jul 2023
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.