Symptoms

FOS v8.1.x 和 FOS v8.2.x 之间的固件下载

影响:
  • 定向器交换机冷恢复
  • 用户执行 lscfg 操作,操作失败并发生 PMGR-1006 raslog 事件
环境:
Dell EMC 硬件:Connectrix ED-DCX6-4B
Dell EMC 硬件:Connectrix ED-DCX6-8B
Dell EMC 软件:Connectrix B 系列 Fabric OS (FOS) 8.1
Dell EMC 软件:Connectrix B 系列 Fabric OS (FOS) 8.2

问题:
从 FOS 8.1.x 升级到 FOS 8.2.x 可能会在虚拟构造 (VF) 配置文件的 PORTMAP 条目中创建一组无效的端口范围。
只有在从较早的 FOS 版本升级到 FOS 8.2.0 或更高版本,并且 PORTMAP 条目大小增长到大于或等于 1024 时,才会在 X6-8 或 X6-4 定向器交换机上发生此情况。

只有在使用“lscfg”CLI 命令在逻辑交换机之间反复移动端口后,PORTMAP 条目大小才会增长到超过 1024 个字符。可以通过以下方式计算当前的 PORTMAP 条目大小:
  • 使用 CLI 命令“configupload-vf”,找到已上传的配置文件,然后运行“grep PORTMAP <uploaded-configuration-filename>”,并计算从“F”或“G”到结束“]”字符的字符数。
出厂安装 FOS 8.2.0 或更高版本的 X6-8 或 X6-4 定向器交换机将不会发生此问题,除非它们被降级为 8.2.0 之前的 FOS 版本,然后再次升级到 FOS 8.2.0 或更高版本。

症状:
未启用 VF 的交换机:
  • 未启用 VF 的用户将不会看到任何外部症状。
  • 检查 VF 配置中的 PORTMAP 条目可能会在表映射中显示无效的端口号,但如果未启用 VF,这些无效的端口号条目将不会影响交换机的运行。
  • 1800 和 3399 之间的任何端口号均被视为“无效条目”。
  • 这不会影响没有 VF 的系统。但是,如果正在使用逻辑构造,或计划在将来启用逻辑构造,则应移除这些无效条目。
如果字符限制高于或接近 1024,则应减少字符限制以解决/防止上述症状。

启用了 VF 的交换机:
仅当 VF 配置文件中的 PORTMAP 条目的大小超过 1024 个字时,已启用 VF 的用户才会看到影响。
如果端口在一个逻辑交换机和另一个逻辑交换机之间重复移动,则会发生这种情况。管理员可以验证表的大小,以确定是否接近故障点。

检查 PORTMAP:
    1. 以管理员用户身份运行命令configupload -vf。输出可用于查看 VF 配置文件中的 PORTMAP 条目。
    它同时显示 FC 和 GE PORTMAP,并为所有逻辑交换机显示 PORTMAP。
    1. 要手动检查 1024 限制,请计算从“F”或“G”到最终的“]”的字符数,或者联系支持部门。
    示例:
    上传的示例文件中的 FC PORTMAP 包含 528 个字符。
    上传的示例文件中的 GE PORTMAP 包含 510 个字符。

    达到字符限制之前的症状:

    上传的文件示例:
    # BROCADE
    # VERSION 822
    # PLATFORM 166
    # SWITCHCONF
    SYSTEM max
    ATTRIBUTE SYS_NAME:sw0
    ATTRIBUTE VF:0
    ATTRIBUTE ETHSW_ENABLED:0
    ATTRIBUTE BLADE_IDS1:00afafbab20000
    ATTRIBUTE BLADE_IDS2:b1b10000000000
    SWITCH fcsw-0
    ATTRIBUTE FID:128 SWNAME:sw0 USR:3400 GE:256 ICL:128 DS:1 TID:775683370
    PIN 5
    PORTMAP FC:[0-447,768-895,1152-1215,1816-1823,1848-1855,1880-1887,1912-1919,1944-1951,1976-1983,2008-2015,2040-2047,2072-2079,2104-2111,2136-2143,2168-2175,2200-2207,2232-2239,2264-2271,2296-2303,2328-2335,2360-2367,2392-2399,2424-2431,2456-2463,2488-2495,2520-2527,2552-2559,2584-2591,2616-2623,2648-2655,2680-2687,2712-2719,2744-2751,2776-2783,2808-2815,2840-2847,2872-2879,2904-2911,2936-2943,2968-2975,3000-3007,3032-3039,3064-3071,3096-3103,3128-3135,3160-3167,3192-3199,3224-3231,3256-3263,3288-3295,3320-3327,3352-3359,3384-3391]
    PORTMAP GE:[0-255,1816-1823,1848-1855,1880-1887,1912-1919,1944-1951,1976-1983,2008-2015,2040-2047,2072-2079,2104-2111,2136-2143,2168-2175,2200-2207,2232-2239,2264-2271,2296-2303,2328-2335,2360-2367,2392-2399,2424-2431,2456-2463,2488-2495,2520-2527,2552-2559,2584-2591,2616-2623,2648-2655,2680-2687,2712-2719,2744-2751,2776-2783,2808-2815,2840-2847,2872-2879,2904-2911,2936-2943,2968-2975,3000-3007,3032-3039,3064-3071,3096-3103,3128-3135,3160-3167,3192-3199,3224-3231,3256-3263,3288-3295,3320-3327,3352-3359,3384-3391]

    也可以在 RAS supportsave 文件中找到该 PORTMAP。(不是 RAS_POST;仅 RAS。)

    它可能会出现多次,因为 supportsave 会对 vf-conf.<swbd>、switch-conf.<swbd> 和 .save 文件执行“cat”操作。vf-conf.<swbd> 的“cat”是最佳选择。
    来自 supportsave 文件 switch0-xxx.xxx.xx.xxx-S1cp-202001152137.RAS.txt 的示例:
    ********************************************************
    SWITCHCMD /bin/cat /etc/fabos/config/vf-conf.166:
    ********************************************************
    /bin/cat /etc/fabos/config/vf-conf.166:
    SYSTEM max
    ATTRIBUTE SYS_NAME:sw0
    ATTRIBUTE VF:0
    ATTRIBUTE ETHSW_ENABLED:0
    ATTRIBUTE BLADE_IDS1:00afaf00000000
    ATTRIBUTE BLADE_IDS2:b1b10000000000
    SWITCH fcsw-0
    ATTRIBUTE FID:128 SWNAME:sw0 USR:3400 GE:256 ICL:128 DS:1 TID:901059396
    PIN 5
    PORTMAP FC:[0-447,768-895,1152-1215,1816-1823,1848-1855,1880-1887,1912-1919,1944-1951,1976-1983,2008-2015,2040-2047,2072-2079,2104-2111,2136-2143,2168-2175,2200-2207,2232-2239,2264-2271,2296-2303,2328-2335,2360-2367,2392-2399,2424-2431,2456-2463,2488-2495,2520-2527,2552-2559,2584-2591,2616-2623,2648-2655,2680-2687,2712-2719,2744-2751,2776-2783,2808-2815,2840-2847,2872-2879,2904-2911,2936-2943,2968-2975,3000-3007,3032-3039,3064-3071,3096-3103,3128-3135,3160-3167,3192-3199,3224-3231,3256-3263,3288-3295,3320-3327,3352-3359,3384-3391]
    PORTMAP GE:[0-255,1816-1823,1848-1855,1880-1887,1912-1919,1944-1951,1976-1983,2008-2015,2040-2047,2072-2079,2104-2111,2136-2143,2168-2175,2200-2207,2232-2239,2264-2271,2296-2303,2328-2335,2360-2367,2392-2399,2424-2431,2456-2463,2488-2495,2520-2527,2552-2559,2584-2591,2616-2623,2648-2655,2680-2687,2712-2719,2744-2751,2776-2783,2808-2815,2840-2847,2872-2879,2904-2911,2936-2943,2968-2975,3000-3007,3032-3039,3064-3071,3096-3103,3128-3135,3160-3167,3192-3199,3224-3231,3256-3263,3288-3295,3320-3327,3352-3359,3384-3391]


    达到字符限制后的症状:
    pdmd 和 hasmd 崩溃症状:
    由于 pdmd 崩溃,备用 CP2 通过发起重启到 CP1 来进行接管。

    然后,CP2 上触发 hasmd 死机,导致交换机上的双处理器重启以及后续的冷恢复。
    1. 活动 CP1 崩溃的 pdm
    [KSWD-1002], 204763/5877, SLOT 1 | FFDC | CHASSIS, WARNING, , Detected termination of process pdmd:2942
    [HAM-1014], 204765/5878, SLOT 1 | CHASSIS, CRITICAL, , Non restartable component (pdm (pid=2942)) died
    1. 备用 CP2 接管,但备用 CP2 也随 hasmd 崩溃
    [HAM-1004], 152469/1316, SLOT 2 | CHASSIS, INFO, BPGLCG01SL35V, Processor rebooted - Reset., reboot.c
    1. 活动 CP 启动重置待机和冷恢复。
    [EM-5012], 204809/0, SLOT 1 | CHASSIS, INFO, BPGLCG01SL35V, start emd FSS_RECOV_COLD
    [HAM-1004], 5879, SLOT 1 | CHASSIS, INFO, BPGLCG01SL35V, Processor rebooted - Reset.
    [HAM-1004], 5942, SLOT 2 | CHASSIS, INFO, BPGLCG01SL35V, Processor rebooted - Reset.
    • Switchshow 可能有永久禁用的端口,并显示“已获取区域”状态:
    BASE:FID128:admin> switchshow | grep Area
    256 1 32 338840 N16 No_Sync Disabled (Persistent) (Area has been acquired)
    258 1 34 338a40 N16 No_Sync Disabled (Persistent) (Area has been acquired)
    264 1 40 338040 N16 No_Sync Disabled (Persistent) (Area has been acquired)
    266 1 42 338240 N16 No_Sync Disabled (Persistent) (Area has been acquired)
    268 1 44 338440 N16 No_Sync Disabled (Persistent) (Area has been acquired)
    270 1 46 338640 N16 No_Sync Disabled (Persistent) (Area has been acquired)
    272 2 32 339840 N16 No_Sync Disabled (Persistent) (Area has been acquired)
    [truncated]
    • lscfg show 输出可能显示所有端口均为 -1 状态:
    SW0:FID128:admin> lscfg --show
    Created switches FIDs(Domain IDs): 128(ds)(51) 127(51) 100(51) 77(51)
    Slot 1 2 3 4 5 6 7 8 9 10 11 12
    -------------------------------------------------------------------------------
    Port
    0 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    1 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    2 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    3 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    4 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    5 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    6 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    7 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    8 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    9 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    10 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    11 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    12 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    13 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    14 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    15 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    16 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    17 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    18 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    19 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    20 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    21 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    22 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    23 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    24 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    25 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    26 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    27 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    28 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    29 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    30 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    31 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    32 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    33 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    34 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    35 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    36 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    37 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    38 | | | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 | -1 |
    • 当 lscfg --show 输出处于以下状态时,HAfailover 将会失败并显示以下错误:
    hafailover >>>
    can t failover because system is not ready yet or other LS/HA config is in progress.

    Hashow >>>
    Local CP (Slot 6, CP0): Active, Cold Recovered
    Remote CP (Slot 7, CP1): Standby, Faulted
    HA enabled, Heartbeat Up, HA State synchronized

    Cause

    FOS 8.2.x 具有更大的 PORTMAP 缓冲区大小,以支持 FCOE 端口。在 HA 期间从 FOS 8.1.x 同步的数据较小,可能会导致在更高的端口范围中观察到损坏的数据。

    Resolution

    解决办法:
    可以执行非中断进程来修复 VF 配置文件中的 PORTMAP 条目,但需要根访问权限才能发出修复 PORTMAP 条目所需的命令。

    如果 PORTMAP 条目(GE 或 FC)增长到接近 1024 的大小限制,请联系 Brocade 支持。

    然后,会在检查交换机的 SupportSave 之后提供用于修复 VF 配置文件中的 PORTMAP 条目的命令集。

    或者,没有交换机的根访问权限的用户可以遵循中断恢复流程:
    1. 运行命令 configupload -vf
    2. 手动修改上传的 VF 配置文件,使其不包含具有 1800 和 3399 之间的端口号的范围
    3. 运行命令 configdownload -vf(使用修改后的 VF 配置文件)
    这将导致交换机自动冷重启,因为安装了新的修复后的 PORTMAP。

    解决方法: 
    1. 直接从 FOS 8.1.x 升级到 FOS 8.2.2b 或更高版本。
    2. 如果机箱已升级到早于 FOS 8.2.x 的版本且禁用了 VF,则无需执行任何操作。
    3. 如果机箱已升级到早于 FOS 8.2.x 的版本且启用了 VF,并且计划的逻辑构造之间没有端口移动,则无需立即采取措施。
    4. 如果机箱已升级到早于 FOS 8.2.x 的版本且启用了 VF,并且计划的逻辑构造之间有端口移动(通过 lscfg),请联系 Brocade 支持以检查并清理 VF 配置文件中的 PORTMAP 条目。