MFE zDP:QUERY 命令的 RC 不正确。引入了新消息 EIP0287W/E

Summary: QUERY 命令的 RC 不正确

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

当 TGT 中的其中一个 PowerMax 系统离线时,QUERY TGT、STATUS、DEVICE 命令将返回 RC=0。   
  
当 VDG 包含已从 PowerMax 系统中删除的设备时,QUERY VDG 命令将返回 RC=0。    

zDP Definition Utility 已更新,以根据MAX_RC和警告/错误消息严重性设置最终返回代码。
                                               
如果 PowerMax 系统上不存在设备,则 QUERY 输出中的设备条目将标记为“*”。      
A new message will also be issued:                           
EIP0287W/E VDG , SYMM , some devices were not found on the controller 

Cause

这是由于软件问题造成的。

Resolution

永久修复: 
  • 对于 Mainframe Enablers 8.5,已开发 PTF SF85107 来纠正此问题。可从 Dell 在线支持下载。

Additional Information

PTF 护盖说明: 
 
++PTF(SF85107) REWORK(2021333) .                               
++VER(Z038) FMID(SSCF850)                                      
      PRE(                                                     
          SF85068 SF85084                                       
          )                                                    
   /*                                                          
*------------------------------------------------------------- 
* PROBLEM DESCRIPTION(S):                                       
* ------------------------------------------------------------ 
* PROBLEM FIXED: OPT 590911 585747                             
* USERS AFFECTED: zDP users                                    
* PROBLEM DESCRIPTION: Incorrect RC for the QUERY command      
* DESCRIPTION DETAIL:                                          
*                                                              
* The QUERY TGT,STATUS,DEVICE command returns RC=0 when one    
* of the PowerMax systems in TGT is offline.                    
* The QUERY VDG command returns RC=0 when the VDG contains     
* devices that have been deleted from the PowerMax system.     
*                                                              
* PROBLEM RESOLUTION:                                           
*                                                              
* zDP Definition Utility has been updated to set final return  
* code based on the MAX_RC and the warning/error message       
* severity.                                                     
* If a device doesn't exist on a PowerMax system, the device   
* entry in the QUERY output will be marked with a '*'.         
* A new message will also be issued:                           
* EIP0287W/E VDG , SYMM , some       
* devices were not found on the controller                     
*                                                               
*                                                              
* MODULES: EIPINIT                                             
*          EIPMTBL                                             
*                                                               
* ------------------------------------------------------------ 
* SF85107 29 Nov 2021 12:03:35                                 
* ------------------------------------------------------------ 
*  OPT Summary                                                  
*  The following OPTs were addressed by this PTF:              
*                                                              
*    585747  590911                                            
*                                                               
*------------------------------------------------------------- 

Affected Products

Mainframe Enablers
Article Properties
Article Number: 000196303
Article Type: Solution
Last Modified: 22 Jul 2023
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.