MFE SCF:扩展设置可与 RDF 定义的企业 GNS 组配合使用,或者为企业 GNS 组错误地阻止删除 RDF 组

Summary: 扩展设置适用于 RDF 定义的企业 GNS 组,但企业 GNS 组应禁用扩展。 删除企业 GNS 组的 RDF 组被错误地阻止。

This article may have been automatically translated. If you have any feedback regarding its quality, please let us know using the form at the bottom of this page.

Article Content


Symptoms

企业 GNS 组错误地允许 EXTEND 函数。此外,企业 GNS 组的 REMOVE RDF GROUP 被错误地阻止。

示例(Dell EMC CS 实验): 
DEFINE ENTERPRISE -
GROUP 'GNS_GNSENTEX' -
INCLUDE RDF GROUP = 000120200131,(LCL=03C4) -

DEFINE ENTERPRISE ANY GROUP 'GNS_GNSENTEX' EXTEND -
INCLUDE RDF GROUP=000120200246(LCL=3C5)

DEFINE OF GROUP 'GNS_GNSENTEX'
COMPLETED WITH RETURN CODE: 0-0
REASON 0 = OK
预期结果为:
DEFINE OF GROUP 'GNS_GNSENTEX'
COMPLETED WITH RETURN CODE: 8-33
REASON 33 = ENTERPRISE GROUPS MAY NOT BE EXTENDED
示例(Dell EMC CS 实验):
REMOVE FROM GROUP 'GNS_GNSENTRM' RDF GROUP=000120200246(INCLUDE=3C5)

REMOVE FROM GROUP 'GNS_GNSENTRM'
COMPLETED WITH RETURN CODE: 8-33
REASON 33 = ENTERPRISE GROUPS MAY NOT BE EXTENDED

Cause

这是由于软件问题造成的。

Resolution

永久修复:
  • 对于 Mainframe Enablers 8.5,已开发 PTF SF85121 来纠正此问题。可从 Dell 在线支持下载。
  • 对于 Mainframe Enablers 8.4,已开发 PTF SF84163 来纠正此问题。可从 Dell 在线支持下载。

Article Properties


Affected Product

Mainframe Enablers

Last Published Date

22 Jul 2023

Version

5

Article Type

Solution