Article Number: 000206651
Po zainstalowaniu pakietu HealthCheck Release można uruchomić test baterii, uruchamiając następujące polecenie:
# isi healthcheck run battery_test_status -v
Po uruchomieniu tego polecenia podaje nazwę stanu polecenia. Użyj tego polecenia z poleceniem widoku, aby sprawdzić stan.
Example:
# isi healthcheck run battery_test_status -v Queued evaluation to run: battery_test_status20221214T1439 # isi healthcheck view battery_test_status20221214T1439 ID: battery_test_status20221214T1439 Checklist: battery_test_status Overrides: - Parameters: {} Run Status: Completed Result: Fail Failure: CRITICAL 50 [NODE 1] battery_test_status * Battery 1 has 0 most recent test failures, threshold is 3 * Battery 1 Permanent fault status is False * Battery 1 Capacity Degradation 421234 mAh, 40.12% * Battery 1 Replacement required prior to upgrade Logs: /ifs/.ifsvar/modules/healthcheck/results/evaluations/battery_test_status20221214T1439
Jeśli pole obniżenia pojemności baterii 1 ma wartość mniejszą niż 45%, można przystąpić do aktualizacji pakietu oprogramowania wewnętrznego węzła.
Jeśli pole degradacji pojemności baterii 1 jest równe lub większe niż 45%, NIE NALEŻY INSTALOWAĆ PAKIETU OPROGRAMOWANIA WEWNĘTRZNEGO WĘZŁA. Otwórz zgłoszenie serwisowe z pomocą techniczną i poproś o wymianę zapasowej baterii.
W powyższym przykładzie przed kontynuacją aktualizacji oprogramowania wewnętrznego węzła należy otworzyć zgłoszenie serwisowe i wymienić zapasową baterię.
Isilon A200, Isilon A2000, Isilon F800, Isilon F810, Isilon Gen6, Isilon H400, Isilon H500, Isilon H5600, Isilon H600, Isilon HD400