Article Number: 000217091
PDR5 - Disk arg1 in Backplane 1 in of RAID Controller in SL3 is removed PDR1001 - Fault detected on drive arg1 in disk drive bay CTL137 - iDRAC is unable to successfully communicate with the device PCIe SSD in Slot X in Bay Y PR8 - Device not detected: Dell NVMe PCIe SSD Configuration Data(PCIe SSD in Slot X in Bay Y)
Dell Technologies recommends updating the PM1733a/PM1735a drive firmware at the earliest available opportunity to avoid future occurrences of this error condition. Dell Samsung PM1733a and PM1735a drives can both be updated using these new firmware versions, but this error condition is only observed on PM1735a.
Once a drive has entered into a failed state, it is not possible to recover or update it.
Note: Instant Secure Erase (ISE) and Federal Information Processing Standards (FIPS) versions of the drive, each require a different firmware package to update.
PM1733a/PM1735a ISE firmware 1.1.1 (JN1W7)
https://www.dell.com/support/home/en-us/drivers/driversdetails?driverid=JN1W7
PM1733a/PM1735a FIPS firmware 3.1.3 (3YYTC)
https://www.dell.com/support/home/en-us/drivers/driversdetails?driverid=3YYTC
Dell PowerEdge Express Flash NVMe PCIe SSD
09 Feb 2024
7
Solution