Cisco: Oplysninger om grænseflade og kommandokode mangler i %FCNS-3-BAD_FRAME syslog-meddelelse

Summary: Oplysninger om grænseflade og kommandokode mangler i %FCNS-3-BAD_FRAME syslog-meddelelse

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Syslog-fejlmeddelelsen mangler grænsefladen, hvor kommandoen kom fra, og den mangler den kommandokode, der var ugyldig.

 %FCNS-3-BAD_FRAME: %$VSAN 99%$ : Invalid CT command code

Found in code NX-OS 8.1.1

Der mangler også en kildegrænseflade til fejlmeddelelsen i show fcns internal errors:

...

8) Event:E_DEBUG, length:94, at 651075 usecs after Wed Nov 20 10:58:26 2019
    [825307441]  ns_handle_command(6273): vsan:20 FC2: Received a frame with invalid CT command code 1801


9) Event:E_DEBUG, length:94, at 647947 usecs after Wed Nov 20 10:58:26 2019
    [825307441]  ns_handle_command(6273): vsan:20 FC2: Received a frame with invalid CT command code 3901

Cause

Cisco-fejl – CSCvs19448

Dette sker, når den tilsluttede enhed sender en ugyldig FCNS Kommando.

Resolution

Syslog er blevet ændret, så den indeholder den ugyldige kommandokode, FCID og grænsefladen som følger:

 switchname %FCNS-3-BAD_FRAME: %$VSAN 1%$ : Invalid CT command code[0xfef7] from device[0xea0000], interface[fc1/14]

Der blev foretaget en lignende ændring af meddelelsen i showet fcns interne fejl.

Lave:
Opgrader til NX-OS 8.42 og nyere

Affected Products

Connectrix MDS-Series Firmware 8.X
Article Properties
Article Number: 000220758
Article Type: Solution
Last Modified: 23 Feb 2026
Version:  3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.