Cisco: Oplysninger om grænseflade og kommandokode mangler i %FCNS-3-BAD_FRAME syslog-meddelelse
Summary: Oplysninger om grænseflade og kommandokode mangler i %FCNS-3-BAD_FRAME syslog-meddelelse
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Syslog-fejlmeddelelsen mangler grænsefladen, hvor kommandoen kom fra, og den mangler den kommandokode, der var ugyldig.
%FCNS-3-BAD_FRAME: %$VSAN 99%$ : Invalid CT command code
Found in code NX-OS 8.1.1
Der mangler også en kildegrænseflade til fejlmeddelelsen i show fcns internal errors:
...
8) Event:E_DEBUG, length:94, at 651075 usecs after Wed Nov 20 10:58:26 2019
[825307441] ns_handle_command(6273): vsan:20 FC2: Received a frame with invalid CT command code 1801
9) Event:E_DEBUG, length:94, at 647947 usecs after Wed Nov 20 10:58:26 2019
[825307441] ns_handle_command(6273): vsan:20 FC2: Received a frame with invalid CT command code 3901Cause
Cisco-fejl – CSCvs19448
Dette sker, når den tilsluttede enhed sender en ugyldig FCNS Kommando.
Resolution
Syslog er blevet ændret, så den indeholder den ugyldige kommandokode, FCID og grænsefladen som følger: switchname %FCNS-3-BAD_FRAME: %$VSAN 1%$ : Invalid CT command code[0xfef7] from device[0xea0000], interface[fc1/14]
Der blev foretaget en lignende ændring af meddelelsen i showet fcns interne fejl.
Lave:
Opgrader til NX-OS 8.42 og nyere
Affected Products