Cisco: Interface- en opdrachtcodegegevens ontbreken in syslog-bericht %FCNS-3-BAD_FRAME
Summary: Informatie over interface en opdrachtcode ontbreekt in syslog-bericht %FCNS-3-BAD_FRAME
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
De syslog-foutmelding mist de interface waar de opdracht vandaan kwam en de ongeldige opdrachtcode ontbreekt.
%FCNS-3-BAD_FRAME: %$VSAN 99%$ : Invalid CT command code
Found in code NX-OS 8.1.1
De broninterface ontbreekt ook voor de foutmelding in show fcns internal errors:
...
8) Event:E_DEBUG, length:94, at 651075 usecs after Wed Nov 20 10:58:26 2019
[825307441] ns_handle_command(6273): vsan:20 FC2: Received a frame with invalid CT command code 1801
9) Event:E_DEBUG, length:94, at 647947 usecs after Wed Nov 20 10:58:26 2019
[825307441] ns_handle_command(6273): vsan:20 FC2: Received a frame with invalid CT command code 3901Cause
Cisco-bug - CSCvs19448
Dit gebeurt wanneer het aangesloten apparaat een ongeldig FCNS Opdracht.
Resolution
De syslog is aangepast om de ongeldige opdrachtcode, de FCID en de interface als volgt op te nemen: switchname %FCNS-3-BAD_FRAME: %$VSAN 1%$ : Invalid CT command code[0xfef7] from device[0xea0000], interface[fc1/14]
Een soortgelijke wijziging is aangebracht in het bericht in show fcns interne fouten.
Fix:
Upgrade naar NX-OS 8.42 en hoger