Cisco: Grensesnitt- og kommandokodeinformasjon mangler i %FCNS-3-BAD_FRAME syslog-meldingen

Summary: Grensesnitt- og kommandokodeinformasjon mangler i %FCNS-3-BAD_FRAME syslog-meldingen

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Syslog-feilmeldingen mangler grensesnittet der kommandoen kom fra, og den mangler kommandokoden som var ugyldig.

 %FCNS-3-BAD_FRAME: %$VSAN 99%$ : Invalid CT command code

Found in code NX-OS 8.1.1

Kildegrensesnittet mangler også for feilmeldingen i show fcns internal errors:

...

8) Event:E_DEBUG, length:94, at 651075 usecs after Wed Nov 20 10:58:26 2019
    [825307441]  ns_handle_command(6273): vsan:20 FC2: Received a frame with invalid CT command code 1801


9) Event:E_DEBUG, length:94, at 647947 usecs after Wed Nov 20 10:58:26 2019
    [825307441]  ns_handle_command(6273): vsan:20 FC2: Received a frame with invalid CT command code 3901

Cause

Cisco-feil – CSCvs19448

Dette skjer når den tilkoblede enheten sender inn en ugyldig FCNS Kommandoen.

Resolution

Systemloggen er endret for å inkludere den ugyldige kommandokoden, CIDen og grensesnittet som følger:

 switchname %FCNS-3-BAD_FRAME: %$VSAN 1%$ : Invalid CT command code[0xfef7] from device[0xea0000], interface[fc1/14]

En lignende endring ble gjort i meldingen i showet fcns interne feil.

Fikse:
Oppgrader til NX-OS 8.42 og nyere