Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

IDPA: Deployment fails with error "DDVE network assignment failed" due to FQDN with double hyphen

Summary: This KB covers a deployment failure where DDVE/Protection Storage deployment fails with error "DDVE network assignment fails" due to bad hostname. Integration Data Protection Appliance does not allow a Protection Storage/DDVE hostname with consecutive hyphens. ...

This article may have been automatically translated. If you have any feedback regarding its quality, please let us know using the form at the bottom of this page.

Article Content


Symptoms

The Integration Data Protection Appliance ACM UI shows the following error for deployment:
The IDPA ACM UI shows the following error for deployment


ACM server.log shows the following error message:
2024-03-13 18:25:14,293 INFO  [pool-13-thread-4]-vsphereadapter.GuestManager: execute - >Executind command on Guest OS.2024-03-13 18:25:14,346 INFO  [pool-13-thread-4]-vsphereadapter.GuestManager: execute - >Command execution started on Guest OS. Process ID: 135062024-03-13 18:25:14,346 INFO  [pool-13-thread-4]-vsphereadapter.GuestManager: execute - >Waiting for complete command execution on guest OS.2024-03-13 18:25:18,404 ERROR [pool-13-thread-4]-vsphereadapter.GuestManager:  Command execution failed exitcode:92024-03-13 18:25:18,404 ERROR [pool-13-thread-4]-vsphereadapter.GuestManager: execute - >Not able to execute commandcom.emc.vcedpa.common.exception.ApplianceException: Command execution failed on service.        at com.emc.vcedpa.vsphereadapter.GuestManager.execute(GuestManager.java:114) [vcedpa-vsphereadapter-2.7.6.jar:?]        at com.emc.vcedpa.ddadapter.DeployDataDomainVapp.executeCmdWithRetries(DeployDataDomainVapp.java:513) [vcedpa-ddadapter-2.7.6.jar:?]        at com.emc.vcedpa.ddadapter.DeployDataDomainVapp.assignIp(DeployDataDomainVapp.java:408) [vcedpa-ddadapter-2.7.6.jar:?]        at com.emc.vcedpa.ddadapter.DeployDataDomainVapp.run(DeployDataDomainVapp.java:175) [vcedpa-ddadapter-2.7.6.jar:?]        at java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1149) [?:1.8.0_361]        at java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:624) [?:1.8.0_361]        at java.lang.Thread.run(Thread.java:750) [?:1.8.0_361] 
09:15:38,296 ERROR [pool-11-thread-4]-ddadapter.DeployDataDomainVapp: assignIp -->  DDVE network assignment failed.2024-03-08 09:15:38,296 ERROR [pool-11-thread-4]-ddadapter.DeployDataDomainVapp: Exception occurred while executing deploy DD vApp task. 

Cause

Protection Storage/Data Domain contains a hostname with two consecutive hyphens which is not supported. Hence Protection storage does not acquire the correct hostname. This is a product limitation.

For Example:
The hostname "ab-cd--efghif.example.com" has two hyphens. This causes an issue.

Resolution

Use a different hostname/FQDN for Protection Storage without two hyphens (--).
Update the DNS forward and reverse lookup entries. 
Retry the deployment with a new hostname.

Article Properties


Affected Product

PowerProtect Data Protection Appliance, PowerProtect Data Protection Software, PowerProtect Data Protection Hardware

Product

PowerProtect DP4400, PowerProtect DP5300, PowerProtect DP5800, PowerProtect DP8300, PowerProtect DP8800, PowerProtect DP5900, PowerProtect DP8400, PowerProtect DP8900

Last Published Date

14 May 2024

Version

2

Article Type

Solution