Dell Unity: Päivitystä edeltävä kuntotarkistus epäonnistuu ja näyttää virheen: Check_connectemc_sender_1

Summary: Pre-Upgrade Health Check (PUHC) epäonnistuu ja näyttää virheen: ERROR_CODE=alusta::check_connectemc_sender_1|Virhe|PÄIVITYS EI VOI EDETÄ (Dell korjattavissa)

This article may have been automatically translated. If you have any feedback regarding its quality, please let us know using the form at the bottom of this page.

Article Content


Symptoms

Pre-Upgrade Health Check (PUHC) epäonnistuu ja näyttää virheen:
ERROR_CODE=platform::check_connectemc_sender_1|Error|
UPGRADE CANNOT PROCEED.
check_connectemc_sender_1
errors :0x1000300- Operation failed. Error code: 0x1000300 The requested object could not be found on the system. Recheck the command name. 0x6400bee - Failed to perform the operation because connect home has not been configured

Cause

Huomautus: Unity OE 5.3 -versiosta alkaen ConnectHome-yhteysilmoitukset komennolla <serialNumber>@dell.com eivät ole enää oletusarvoisia.

Kun määrität ConnectHome-yhteyttä, liitä mukaan sähköpostiosoite järjestelmän toimialuenimestä tai soveltuva sähköpostiosoite, joka välittää todennuksen SMTP-palvelimeltasi.

Jotta SupportAssist voidaan ottaa käyttöön versiossa 5.3 ja uudemmissa, ConnectEMC:llä on oltava lähettäjäsähköpostiosoite.

Resolution

Ongelman voi ratkaista kahdella tavalla.
  1. Ohita PUHC ja tee päivitys. Lisää lähettäjän sähköpostiosoite myöhemmin.
  2. Lisää lähettäjän sähköpostiosoite nyt ja tee päivitys.


Vaihtoehto 1: Ohita PUHC ja tee päivitys

  1. Suorita seuraava komento:
svc_skip_puhc
  1. Ohita virhe suorittamalla seuraava komento:
+58

50: flr::check_for_disk_transitions
51: flr::check_for_faulted_disks
52: flr::check_for_no_pulled_disks
53: flr::check_for_snaps_in_an_active_state
54: flr::check_movesession_exists
55: slic::check_for_slic_committed
56: platform::check_centralized_esrs_version
57: platform::check_unsupported_proxy
58: platform::check_connectemc_sender
  1. Kun check_connectemc_sender on ohitettu, aloita päivitys Unispheresta.
  2. Lisää ConnectEMC:n lähettäjän sähköpostiosoite. (Katso alla)


Vaihtoehto 2: Lisää lähettäjän sähköpostiosoite ja päivitä

Voit lisätä lähettäjän sähköpostiosoitteen kolmella tavalla:
  1. Unisphere
  2. svc_connectemc komennot
  3. Uemcli-komennot

Unisphere:

SMTP

svc_connectemc:

  1. Näytä ConnectEMC:n tila suorittamalla seuraava komento:
svc_connectemc -s

ConnectEMC: NOTRUNNING DISABLE
  1. Testaa ConnectEMC:n kyky lähettää viesti tukeen seuraavalla komennolla:
spa:/cores/service/user# svc_connectemc -t

ERROR [spa]: Email (ConnectEMC) not configured
  1. Näytä ConnectEMC-määritystiedot suorittamalla seuraava komento:
svc_connectemc -g

INFO [spa]: SMTP Host: smtp.server.com
INFO [spa]: SENDER EMAIL: DP-Unity01@dell.com
INFO [spa]: EMC Destination Email: emailalert@emc.com
  1. Määritä sähköpostiosoite, jota ConnectEMC käyttää hälytysten lähettämiseen suorittamalla alla olevan komennon:
05:57:12 root@CKM002XXXXX929 spa:/cores/service/user# svc_connectemc -m DP-Unity01@dell.com

INFO [spa]: Verifying peer connectivity ...
ERROR [spa]: Email (ConnectEMC) not configured. Please enable connetEMC first.
  1. Ota ConnectEMC käyttöön seuraavalla komennolla:
05:58:30 root@CKM002XXXXX929 spa:/cores/service/user# svc_connectemc --enable 10.1XX.1XX.1X1 --sendermail DP-Unity01@dell.com

INFO [spa]: Verifying peer connectivity ...
INFO [spa]: Enabling ConnectEMC
INFO [spa]: Verifying peer connectivity ...
INFO [spa]: copying connectEMC config to peer
INFO [spa]: Persisting SMTP server configuration
INFO [spa]: Persisting sender email address configuration
INFO [spa]: ConnectEMC has been enabled successfully.
  1. Kun olet ottanut ConnectEMC:n käyttöön, testaa yhteys
    svc_connectemc -t
    INFO [spa]: Test Dialhome request 

Uemcli:

  1. Näytä nykyiset kokoonpanot suorittamalla seuraava komento:
uemcli /sys/support/connecthome show -detail

1:  Enabled       = yes
   SMTP server     = 10.1XX.1XX.1X1
   E-mail from address = (none)@emc.com 
   E-mail to address  = emailalert@emc.com
Jos vahvistat testikomennon ennen ConnectEMC:n käyttöönottoa, se epäonnistuu ja näyttää virheen: 
Operation failed. Error code: 0x1000300
The requested object could not be found on the system. Recheck the command name. (Error Code:0x1000300)
  1. Ota ConnectEMC käyttöön suorittamalla seuraava komento: 
uemcli -d 10.0.0.1 -u local/joe -p Password /sys/support/connecthome set –enable yes –smtpServer 10.10.22.22 -emailFromAddr DP-Unity01@dell.com
Jos testaat ConnectEMC:n käyttöönoton jälkeen, se läpäisee:
09:05:02 root@CKM002XXXXX929 spb:/cores/service/user# uemcli -u admin -securepassword /sys/support/connecthome test
Password:
Storage system address: 127.0.0.1
Storage system port: 443
HTTPS connection

Remote certificate:
Issuer:   CN=DP-UNITY01
Subject:  CN=DP-UNITY01
Valid from: 2020:06:14:07:13:27
Valid to:  2023:06:14:07:13:27
Serial:   00a382cb17422be9fd
Id:     2957123456
Would you like to:
 [1] Accept the certificate for this session
 [2] Reject the certificate
Please input your selection (The default selection is [1]):
Operation completed successfully.
  1. Luettele nykyiset tiedot kokoonpanomuutoksen jälkeen:
uemcli /sys/support/connecthome show -detail

Please input your selection (The default selection is [1]):
1:  Enabled       = yes
   SMTP server     = 10.1XX.1XX.1X1
   E-mail from address = DP-Unity01@dell.com
   E-mail to address  = emailalert@emc.com

Additional Information

Article Properties


Affected Product

Dell EMC Unity Family

Last Published Date

07 Jun 2024

Version

2

Article Type

Solution