Dell Unity: 오류 check_connectemc_sender_1로 인해 업그레이드 전 상태 점검에 실패함(Dell 수정 가능)

Summary: 다음 오류와 함께 PUHC(Pre-Upgrade Health Check)가 실패합니다. ERROR_CODE=플랫폼::check_connectemc_sender_1|오류 |업그레이드를 진행할 수 없습니다.

This article may have been automatically translated. If you have any feedback regarding its quality, please let us know using the form at the bottom of this page.

Article Content


Symptoms

다음 오류와 함께 PUHC(Pre-Upgrade Health Check)가 실패합니다. 
ERROR_CODE=platform::check_connectemc_sender_1|Error|
UPGRADE CANNOT PROCEED.
check_connectemc_sender_1
errors :0x1000300- Operation failed. Error code: 0x1000300 The requested object could not be found on the system. Recheck the command name. 0x6400bee - Failed to perform the operation because connect home has not been configured

Cause

Unity OE 5.3부터는 serialNumber>@dell.com 를 사용하는 <ConnectHome 연결 알림이 더 이상 기본값이 아닙니다.
ConnectHome 연결을 구성할 때 시스템 도메인 이름의 이메일 주소 또는 SMTP 서버에서 인증을 통과하는 해당 이메일 주소를 포함합니다. 

5.3 이상에서 SupportAssist를 활성화하려면 ConnectEMC에 "보낸 사람" 이메일 주소가 있어야 합니다.

Resolution

이 문제를 해결하기 위한 두 가지 옵션이 있습니다.

1. PUHC를 건너뛰고 업그레이드를 수행합니다. 나중에 보낸 사람 이메일 주소를 추가합니다.
2. 지금 보낸 사람 이메일 주소를 추가한 다음 업그레이드를 수행합니다.

옵션 1: PUHC를 건너뛰고 업그레이드 수행
  1. 아래 명령을 실행합니다.
svc_skip_puhc
  1. 아래 명령을 실행하여 오류를 건너뜁니다.
+58

50: flr::check_for_disk_transitions
51: flr::check_for_faulted_disks
52: flr::check_for_no_pulled_disks
53: flr::check_for_snaps_in_an_active_state
54: flr::check_movesession_exists
55: slic::check_for_slic_committed
56: platform::check_centralized_esrs_version
57: platform::check_unsupported_proxy
58: platform::check_connectemc_sender
  1. check_connectemc_sender 건너뛰면 Unisphere에서 업그레이드를 시작합니다.
  2. ConnectEMC의 보낸 사람 이메일 주소를 추가합니다.  (아래 참조)
옵션 2: 보낸 사람 이메일 주소를 추가한 다음 업그레이드

보낸 사람 이메일 주소를 추가하는 세 가지 옵션이 있습니다.
  1. Unisphere
  2. svc_connectemc 명령
  3. uemcli 명령
Unisphere:


SMTP
svc_connectemc:
  1. 아래 명령을 실행하여 ConnectEMC 상태를 표시합니다.
svc_connectemc -s

ConnectEMC: NOTRUNNING DISABLE
      2. 아래 명령을 사용하여 ConnectEMC의 기능을 테스트하여 지원 팀에 메시지를 보냅니다.
spa:/cores/service/user# svc_connectemc -t

ERROR [spa]: Email (ConnectEMC) not configured
    3.  아래 명령을 실행하여 ConnectEMC 구성 세부 정보를 표시합니다.
svc_connectemc -g

INFO [spa]: SMTP Host: smtp.server.com
INFO [spa]: SENDER EMAIL: DP-Unity01@dell.com
INFO [spa]: EMC Destination Email: emailalert@emc.com
   4. 아래 명령을 실행하여 ConnectEMC에서 알림을 보내는 데 사용할 이메일 주소를 설정합니다.
05:57:12 root@CKM002XXXXX929 spa:/cores/service/user# svc_connectemc -m DP-Unity01@dell.com

INFO [spa]: Verifying peer connectivity ...
ERROR [spa]: Email (ConnectEMC) not configured. Please enable connetEMC first.
   5. 아래 명령을 실행하여 ConnectEMC를 활성화합니다.
05:58:30 root@CKM002XXXXX929 spa:/cores/service/user# svc_connectemc --enable 10.1XX.1XX.1X1 --sendermail DP-Unity01@dell.com

INFO [spa]: Verifying peer connectivity ...
INFO [spa]: Enabling ConnectEMC
INFO [spa]: Verifying peer connectivity ...
INFO [spa]: copying connectEMC config to peer
INFO [spa]: Persisting SMTP server configuration
INFO [spa]: Persisting sender email address configuration
INFO [spa]: ConnectEMC has been enabled successfully.
  1. ConnectEMC를 활성화한 후 연결을 테스트합니다. 
    svc_connectemc -t
    INFO [spa]: Test Dialhome request 

UEMCLI:

  1. 아래 명령을 실행하여 현재 구성을 나열합니다.
    uemcli /sys/support/connecthome show -detail
    
    1:  Enabled       = yes
       SMTP server     = 10.1XX.1XX.1X1
       E-mail from address = (none)@emc.com 
       E-mail to address  = emailalert@emc.com
ConnectEMC를 활성화하기 전에 테스트 명령을 확인하면 다음 오류가 발생하며 실패합니다. 
Operation failed. Error code: 0x1000300
The requested object could not be found on the system. Recheck the command name. (Error Code:0x1000300)
      2.  아래 명령을 실행하여 ConnectEMC를 활성화합니다. 
uemcli -d 10.0.0.1 -u local/joe -p Password /sys/support/connecthome set –enable yes –smtpServer 10.10.22.22 -emailFromAddr DP-Unity01@dell.com
  1. ConnectEMC를 활성화한 후 테스트하면 성공적으로 통과합니다.
    09:05:02 root@CKM002XXXXX929 spb:/cores/service/user# uemcli -u admin -securepassword /sys/support/connecthome test
    Password:
    Storage system address: 127.0.0.1
    Storage system port: 443
    HTTPS connection
    
    Remote certificate:
    Issuer:   CN=DP-UNITY01
    Subject:  CN=DP-UNITY01
    Valid from: 2020:06:14:07:13:27
    Valid to:  2023:06:14:07:13:27
    Serial:   00a382cb17422be9fd
    Id:     2957123456
    Would you like to:
     [1] Accept the certificate for this session
     [2] Reject the certificate
    Please input your selection (The default selection is [1]):
    Operation completed successfully.
4. 구성 변경 후의 현재 세부 정보를 나열합니다.
uemcli /sys/support/connecthome show -detail

Please input your selection (The default selection is [1]):
1:  Enabled       = yes
   SMTP server     = 10.1XX.1XX.1X1
   E-mail from address = DP-Unity01@dell.com
   E-mail to address  = emailalert@emc.com

Additional Information

Article Properties


Affected Product

Dell EMC Unity Family

Last Published Date

29 Apr 2024

Version

1