VNX 整合:VNX-FILE 複製健全狀況檢查程式-使用者可更正

Resumen: 本文探討如何在 VNX-FILE 環境中執行健全狀況檢查。此程式會在本機和遠端執行環境中所有控制站的健全狀況檢查。此計畫著重于複製相關資訊。

Este artículo se aplica a: Este artículo no se aplica a: Este artículo no está vinculado a ningún producto específico. En este artículo no se identifican todas las versiones de los productos.

Instrucciones

  1. 將檔案上傳至 VNX-FILE 控制站。上傳後,請使用下列命令解壓縮檔案:  
[nasadmin@CS0 tmp]$ tar -xvf KB000479575-IPRep_Health_Check_V1.3.tar
Replication_Health_Check.pl
[nasadmin@CS0 tmp]$ ls -al
-rw-rw-r-- 1 nasadmin nasadmin 112640 Aug 15 08:01 KB000479575-IPRep_Health_Check_V1.3.tar
-rwxrwxr-x 1 nasadmin nasadmin 102131 Aug 15 07:50 Replication_Health_Check.pl
  1. 使用下列命令確認 MD5SUM 相符:  
[nasadmin@CS0 tmp]$ md5sum *
d621f3e53770a5b6e1d61590562eb718  KB000479575-IPRep_Health_Check_V1.3.tar
8859de64706171fc19e1d245e7b80670  Replication_Health_Check.pl
[nasadmin@CS0 tmp]$

如何啟動健全狀況檢查
  1. 執行下列命令以啟動健全狀況檢查:  
[nasadmin@CS0 tmp]$ ./Replication_Health_Check.pl -full

此計畫需要幾分鐘的時間才能完成。畫面上會顯示摘要輸出,以確認其正在進行中。程式完成後,請依照如何解決任何未發現的問題的指示操作。

除了螢幕輸出之外,還有一個詳細記錄檔會建立並儲存在控制站本機。如需任何錯誤的詳細資訊,請參閱記錄檔。檔案名和位置會有所不同,且會在程式執行時顯示。

新增新專案,即可在系統目前的複寫會話中檢視「即時系統效能輸送量」摘要。這是為了協助顯示「高階」系統效能統計資料。

Información adicional

方案使用
KBA 479575 - VNX-FILE Replication Health Check
This Health Check program will review local and remote nas_replicate sessions.
This program is designed to be executed on the EMC VNX-FILE control station.

########################################################################
  Usage: ./Replication_Health_Check.pl [ -full | -cs | -inter | -repl | -fs | -debug ]
         -full   : Recommended value, runs checks against all configurations
         -cs    : Validates Control Station (CS-CS) communication
         -inter : Validates local and remote interconnects (This is time consuming)
         -repl  : Reviews Replication related statistics
         -fs     : Reviews File System and CKPT settings
         -perf  : Display Replication Performance Statistics (not a health check)
         -debug : Captures FULL debug information, only use if filing a bug
             EXAMPLE ./Replication_Health_Check.pl -cs
             EXAMPLE ./Replication_Health_Check.pl -full
########################################################################

[nasadmin@CS0 tmp]$

Productos afectados

VNX VG10, VNX VG2, VNX VG8, VNX1 Series, VNX2 Series, VNX5100, VNX5150, VNX5200, VNX5300, VNX5400, VNX5500, VNX5600, VNX5800, VNX7500, VNX7600, VNX8000
Propiedades del artículo
Número de artículo: 000009093
Tipo de artículo: How To
Última modificación: 03 ene 2024
Versión:  3
Encuentra las respuestas que necesitas con la ayuda de otros usuarios de Dell
Servicios de asistencia
Comprueba si tu dispositivo está cubierto por los servicios de asistencia.