VNX 整合:VNX-FILE 複製健全狀況檢查程式-使用者可更正
Resumen: 本文探討如何在 VNX-FILE 環境中執行健全狀況檢查。此程式會在本機和遠端執行環境中所有控制站的健全狀況檢查。此計畫著重于複製相關資訊。
Este artículo se aplica a:
Este artículo no se aplica a:
Este artículo no está vinculado a ningún producto específico.
En este artículo no se identifican todas las versiones de los productos.
Instrucciones
- 將檔案上傳至 VNX-FILE 控制站。上傳後,請使用下列命令解壓縮檔案:
[nasadmin@CS0 tmp]$ tar -xvf KB000479575-IPRep_Health_Check_V1.3.tar Replication_Health_Check.pl [nasadmin@CS0 tmp]$ ls -al -rw-rw-r-- 1 nasadmin nasadmin 112640 Aug 15 08:01 KB000479575-IPRep_Health_Check_V1.3.tar -rwxrwxr-x 1 nasadmin nasadmin 102131 Aug 15 07:50 Replication_Health_Check.pl
- 使用下列命令確認 MD5SUM 相符:
[nasadmin@CS0 tmp]$ md5sum * d621f3e53770a5b6e1d61590562eb718 KB000479575-IPRep_Health_Check_V1.3.tar 8859de64706171fc19e1d245e7b80670 Replication_Health_Check.pl [nasadmin@CS0 tmp]$
如何啟動健全狀況檢查
- 執行下列命令以啟動健全狀況檢查:
[nasadmin@CS0 tmp]$ ./Replication_Health_Check.pl -full
此計畫需要幾分鐘的時間才能完成。畫面上會顯示摘要輸出,以確認其正在進行中。程式完成後,請依照如何解決任何未發現的問題的指示操作。
除了螢幕輸出之外,還有一個詳細記錄檔會建立並儲存在控制站本機。如需任何錯誤的詳細資訊,請參閱記錄檔。檔案名和位置會有所不同,且會在程式執行時顯示。
新增新專案,即可在系統目前的複寫會話中檢視「即時系統效能輸送量」摘要。這是為了協助顯示「高階」系統效能統計資料。
Información adicional
方案使用
KBA 479575 - VNX-FILE Replication Health Check This Health Check program will review local and remote nas_replicate sessions. This program is designed to be executed on the EMC VNX-FILE control station. ######################################################################## Usage: ./Replication_Health_Check.pl [ -full | -cs | -inter | -repl | -fs | -debug ] -full : Recommended value, runs checks against all configurations -cs : Validates Control Station (CS-CS) communication -inter : Validates local and remote interconnects (This is time consuming) -repl : Reviews Replication related statistics -fs : Reviews File System and CKPT settings -perf : Display Replication Performance Statistics (not a health check) -debug : Captures FULL debug information, only use if filing a bug EXAMPLE ./Replication_Health_Check.pl -cs EXAMPLE ./Replication_Health_Check.pl -full ######################################################################## [nasadmin@CS0 tmp]$
Productos afectados
VNX VG10, VNX VG2, VNX VG8, VNX1 Series, VNX2 Series, VNX5100, VNX5150, VNX5200, VNX5300, VNX5400, VNX5500, VNX5600, VNX5800, VNX7500, VNX7600, VNX8000Propiedades del artículo
Número de artículo: 000009093
Tipo de artículo: How To
Última modificación: 03 ene 2024
Versión: 3