ECS: GUI Error 6500 (http: 500): Internal Server Error. An internal server error occurred.
Riepilogo: This knowledge article explains why the ECS UI is unable to log in due login Error 6500 (http: 500): Internal Server Error. An internal server error occurred. Please try again.
Questo articolo si applica a
Questo articolo non si applica a
Questo articolo non è legato a un prodotto specifico.
Non tutte le versioni del prodotto sono identificate in questo articolo.
Sintomi
When logging into the UI on a specific node, the following error is seen on the dashboard or end user license agreement notification:
Causa
There are three ECS services responsible for UI login, stat, "ecsportalsvc," and "obcontrolsvc" - these have stale entries which are not allowing the UI to log in.
Risoluzione
On the concerning node, restart the stat, ecsportalsvc, and obcontrolsvc. There is no impact on restarting these services but it should be noted that any alerts generated on the UI on another node are now linked to these restarts:
Using service tools:
admin@node1:~> svc_node services restart -nw 10 -srv stat ecsportalsvc objcontrolsvc -n self Starting utility inside a screen session
Confirm on the concerning node (rack 1 node 1) that the services have restarted and ensure that there are no services that are not running:
admin@node1:~> svc_node services -status
svc_node v1.2.1 (svc_tools v2.1.0) Started 2022-02-25 11:40:49
Node r1n1:
Services running:
fabric-agent
blobsvc (102925) Started: 2021-12-20 17:07:17 cm (102859) Started: 2021-12-20 17:07:17
coordinatorsvc (102843) Started: 2021-12-20 17:07:17 dataheadsvc (102935) Started: 2021-12-20 17:07:17
dtquery (102951) Started: 2021-12-20 17:07:17 ecsportalsvc (66505) Started: 2022-02-25 11:31:08
eventsvc (102932) Started: 2021-12-20 17:07:17 georeceiver (102950) Started: 2021-12-20 17:07:17
metering (102908) Started: 2021-12-20 17:07:17 objcontrolsvc (69329) Started: 2022-02-25 11:31:32
resourcesvc (102939) Started: 2021-12-20 17:07:17 rm (102851) Started: 2021-12-20 17:07:17
sr (102905) Started: 2021-12-20 17:07:17 ssm (102899) Started: 2021-12-20 17:07:17
stat (65535) Started: 2022-02-25 11:30:55 storageserver (102896) Started: 2021-12-20 17:07:17
vnest (102847) Started: 2021-12-20 17:07:17
Services not running:
<none>
Return to the ECS UI and you can log in without issue.
Prodotti interessati
ECSProdotti
ECS Appliance, ECS Appliance Gen 1, ECS Appliance Gen 2, ECS Appliance Gen 3Proprietà dell'articolo
Numero articolo: 000196746
Tipo di articolo: Solution
Ultima modifica: 05 mar 2024
Versione: 8
Trova risposta alle tue domande dagli altri utenti Dell
Support Services
Verifica che il dispositivo sia coperto dai Servizi di supporto.