Connectrix B-Series: Device Logging In as a Loopback

概要: This article explains why a Connectrix B-Series switch port may detect an attached HBA or storage device as a loopback port and how to troubleshoot the condition.

この記事は次に適用されます: この記事は次には適用されません: この記事は、特定の製品に関連付けられていません。 すべての製品パージョンがこの記事に記載されているわけではありません。

現象

An HBA or storage device automatically configures as a loopback port on a Connectrix B-Series switch.

 

原因

This could be caused by the controller configuration on the HBA or storage device.

 

解決方法

Check whether the end device is configured for Fibre Channel Arbitrated Loop (FC-AL). Also check the integrity of the SFP and cable. Then reset the port as follows:

  • portcfgpersistentdisable
  • portcfgdefault
  • portcfgpersistentenable

If the status of the port is still loopback after performing the above, move the cable to a free port. If the issue follows the cable, it is likely an issue with the connected device. Further troubleshooting must be performed at that end.

 