PowerPath for AIX 6.4: powerdd: MpxPeriodicCallbackDaemon race condition crash
概要: PowerPath for AIX 6.4: powerdd: MpxPeriodicCallbackDaemon race condition crash
この記事は次に適用されます:
この記事は次には適用されません:
この記事は、特定の製品に関連付けられていません。
すべての製品パージョンがこの記事に記載されているわけではありません。
現象
Dell EMC SW: PowerPath for AIX 6.4
CRASH INFORMATION:
CPU 16 CSA F00000002FF47600 at time of crash, error code for LEDs: 30000000
pvthread+010300 STACK:
[F1000000C07A8608]powerdd:PowerEnqueue+000028 (F1000000C04DFEF0, 0000000000000000)
[F1000000C07AAC0C]powerdd:PowerGetSemaNew+00020C (F1000000C04DFE90, 0000000100000001)
[F1000000C07AAD78]powerdd:PowerGetSema+000018 (F1000000C04DFE90)
[F1000000C04D249C]mpxext:MpxGetHostInfo+00009C (F1000000C04DFF60, F1000000C04DC940)
[F1000000C049815C]mpxext:MpxDeviceMountStatsRpt+00005C (F1000A03F0900800, 15C06FB653F3BC50)
[F1000000C049AA6C]mpxext:MpxPeriodicCallout+001EEC (F1000A03F01C2100)
[F1000000C07AD4CC]powerdd:PowerServiceDaemonQ+00010C (F1000A03F06D3E00)
[F1000000C07CDCD4]powerdd:PowerServiceDaemonQWrap+000074 (0000000000000000, 0FFFFFFFF3FFFFF0,
0000000800000008)
[00014D70].hkey_legacy_gate+00004C ()
[0029B310]procentry+000010 (??, ??, ??, ??)
[kdb_real_mem] no real storage @ FFFFFFFFFFF5D50
(16)> th
SLOT NAME STATE TID PRI RQ CPUID CL WCHAN
pvthread+010300 259*MpxPerio RUN 103006B 03C 16 0
NAME................ MpxPeriodicCallbackDaemon
FLAGS............... KTHREAD
..
(16)> vmlog
Most recent VMM errorlog entry
Error id = DSI_PROC
Exception DSISR/ISISR = 000000000A000000
Exception srval = 00007FFFFFFFD080
Exception virt addr = 0000000000000008
Exception value = 00000086 EXCEPT_PROT
(16)>
原因
PowerPath for AIX 6.4 bug
A race condition due to a NULL de-reference in the thread involving multiple function calls from PowerPath 6.4 code.
解決方法
Workaround
Disable the "device in use to array report" feature.
Fix
Fixed in PowerPath for AIX 7.0 which is currently available for download at the support site.
Disable the "device in use to array report" feature.
Fix
Fixed in PowerPath for AIX 7.0 which is currently available for download at the support site.
その他の情報
The following command can be used to disable the device in use to array report feature:
powermt set dev_inuse_to_array_report=off class=symm
The following command can be used to confirm that the device in use to array report feature is disabled:
# powermt display options
Show CLARiiON LUN names: true
Path Latency Monitor: Off
Performance Monitor: disabled
Autostandby: IOs per Failure (iopf): enabled
iopf aging period : 1 d
iopf limit : 6000
Storage
System Class Attributes
------------ ----------
Symmetrix periodic autorestore = on
reactive autorestore = on
status = managed
proximity based autostandby = off
auto host registration = enabled
autopath mask counter = enabled
autopath array controlled counter = enabled
device to array performance report = enabled
device in use to array report = disabled
This bug is specific to PowerPath for AIX 6.4.
This is an isolated corner case, the chance of hitting the issue is remote.
Note: If you are running any microcode version below 5978.221.221 then there won't be any functionality impact.
If you running microcode 5978.221.221 above this version then turning this parameter off, a storage admin will
not know if the device is in use or not from the SYMM array perspective.
powermt set dev_inuse_to_array_report=off class=symm
The following command can be used to confirm that the device in use to array report feature is disabled:
# powermt display options
Show CLARiiON LUN names: true
Path Latency Monitor: Off
Performance Monitor: disabled
Autostandby: IOs per Failure (iopf): enabled
iopf aging period : 1 d
iopf limit : 6000
Storage
System Class Attributes
------------ ----------
Symmetrix periodic autorestore = on
reactive autorestore = on
status = managed
proximity based autostandby = off
auto host registration = enabled
autopath mask counter = enabled
autopath array controlled counter = enabled
device to array performance report = enabled
device in use to array report = disabled
This bug is specific to PowerPath for AIX 6.4.
This is an isolated corner case, the chance of hitting the issue is remote.
Note: If you are running any microcode version below 5978.221.221 then there won't be any functionality impact.
If you running microcode 5978.221.221 above this version then turning this parameter off, a storage admin will
not know if the device is in use or not from the SYMM array perspective.