PowerFlex 4.X: Events and alerts Configure an external source and Configure a destination
概要: PowerFlex Manager enables you to register a notification receiver for pushing alert and event messages through webhooks to a target system,for example, BigPanda.
手順
Events and alerts
A source is used to configure the reception of external events and syslog content.
A destination is used to configure the ability to send events and alerts information out. A destination is always external. SupportAssist, email, SNMP, webhooks, and remote syslog are considered destinations.
Notification policies define what information is sent to each destination. Events and alerts exist irrespective of whether notification policies are created.
SNMP sources are not automatically discovered and must be configured to receive events about these sources. PowerFlex Manager is preconfigured and events, and alerts are automatically available. Resources in the PowerFlex appliance are automatically discovered. Any future resources, for example, switch replacements or additional nodes, are considered external and must be added manually as sources.
PowerFlex Manager enables you to register a notification receiver for pushing alert and event messages through webhooks to a target system,for example, BigPanda.
Configure an external source
You must define a source to enable PowerFlex Manager to receive an external event.
About this task
A syslog source can only go to a syslog destination and does not display in events. An SNMP source, either V2 or V3, displays in events even without a defined notification policy.
For a webhook, the resources are discovered in PowerFlex Manager, and the load balancer IP address needs to be configured on the resources individually. The alerts from individual resources are sent to Webhooks from the source resource type.
SNMPv2c is supported for all Resource types like switch CloudLink, iDRAC.
Steps
- Go to Settings > Events and Alerts > Notification Policies.
- From the Sources pane, click Add.
- Enter a source name and description.
- Configure either SNMP or syslog forwarding and click Submit > Dismiss:
- For SNMPv2c:
- Enter the community string by which the source forwards traps to destinations.
- Enter the same community string for the configured resource. During discovery, if you selected PowerFlex Manager to automatically configure iDRAC nodes to send alerts to PowerFlex Manager, enter the community string that is used in that credential here.
- For SNMPv3:
- Enter the username, which identifies the ID where traps are forwarded on the network management system.
- Select a security level from the following:
- For SNMPv2c:
Security levels and passwords
|
Security level |
Description |
authPassword |
privPassword |
|
Minimum |
noAuthNoPriv |
Not required |
Not required |
|
Moderate |
authNoPriv |
Required |
Not required |
|
Maximum |
authPriv |
Required |
Required |
-
- If you select Syslog, click Enable Syslog.
Configure a destination
Define a location where event and alert data that has been processed by PowerFlex Manager should be sent.
Steps
- Click Settings > Events and Alerts > Notification Policies.
- From the Destinations pane, click Add.
- From the Destinations page:
- Enter the destination name and description.
- From Destination Type menu, select to configure either SNMP, Syslog, or email (SMTP) forwarding.
- Click Next.
- Depending on the destination type, enter the following information:
Destination types and protocol settings
|
Destination type |
Protocol settings |
|
SNMP V2c |
|
|
SNMP V3 |
|
Destination types and protocol settings (continued)
|
Destination type |
Protocol settings |
|
|
|
|
Syslog |
|
|
Email (SMTP) |
|
|
Webhook |
|
- Click Finish.
その他の情報
For Full Guide See Dell PowerFlex Appliance with PowerFlex 4.x Administration Guide