PowerScale HealthCheck 43.0.0 reporting outdated DNOS error
概要: HealthCheck version 43.0.0 incorrectly reporting critical warning about outdated Dell Network Operating System on PowerScale backend switches
この記事は次に適用されます:
この記事は次には適用されません:
この記事は、特定の製品に関連付けられていません。
すべての製品パージョンがこの記事に記載されているわけではありません。
現象
The output from HealthCheck 43.0.0 is:
Example errors found in logs: DNOS (Dell Networking Operating System) version is outdated which can lead to node splits and might lead to a data unavailability situation. It is strongly recommended to upgrade DNOS to the latest certified version.
原因
A change in the algorithm that validates the DNOS version within HealthCheck is reporting any version less than DNOS 10.5.6.9 is outdated.
解決方法
DNOS version 10.5.6.9 is the most recent version qualified for PowerScale backend switches.
There is no issue with any of the previously qualified versions that would create a situation that will cause node splits or data unavailability.
The previously qualified versions are still acceptable for use with all current versions of OneFS.
Previously qualified versions include: 10.5.0.6.C1 10.5.0.6.C2 10.5.0.6.C3 10.5.2.7 10.5.2.9 10.5.2.11 10.5.2.13