PowerEdge R770: Backplane and Cable events during reported during POST
概要: Critical HWC8011 entries for backplane, signal‑power and cable issues appear in System event log on every boot; they persist due to a issue in iDRAC firmware 1.30.10.50 1.30.10.52 and 1.30.30. ...
この記事は次に適用されます:
この記事は次には適用されません:
この記事は、特定の製品に関連付けられていません。
すべての製品パージョンがこの記事に記載されているわけではありません。
現象
SEL and LC Log report various Backplane and Sig Pwr issues.
- Issue only exists in iDRAC firmware 1.30.10.50 and 1.30.10.52. No other iDRAC firmware version is affected.
- Event Code is always HWC8011.
- Severity is always Critical.
Examples:
- HWC8011 - The System Configuration Check operation resulted in multiple Backplane issues.
- HWC8011 - The System Configuration Check operation resulted in multiple Sig Pwr Cable issues.
- HWC8011 - The System Configuration Check operation resulted in multiple Backplane Cable issues.
These events will be present in every boot. The events do not clear on warm boot, cold boot, or AC power cycle. A hardware replacement will not remediate these events.
原因
A supported configuration was inadvertently dropped from iDRAC firmware version 1.30.30.50. The issue is also present in iDRAC firmware version 1.30.30.52.
解決方法
This issue is resolved in iDRAC firmware version 1.30.30.55.
For customers unable to apply this update, a workaround is available.
- Workaround: Roll iDRAC firmware back to March release (version 1.30.10.50) or May release (version 1.30.10.51).
対象製品
PowerEdge R770文書のプロパティ
文書番号: 000491029
文書の種類: Solution
最終更新: 28 7月 2026
バージョン: 1
質問に対する他のDellユーザーからの回答を見つける
サポート サービス
お使いのデバイスがサポート サービスの対象かどうかを確認してください。