手順
- A part replacement may not be required to recover the system.
Step 1: Identify the SDPM Event
Obtain relevant event codes from the following sources:
-
- iDRAC UI
iDRAC Dashboard → Maintenance → System Event Log - RACADM
racadm getsel - DDOS CLI
alerts show current
system show hardware
system show nvram - AutoSupport and SupportAssist / TSR
Review collected AutoSupport and TSR logs.
- iDRAC UI
Record:
-
- Event Code
- Location & component ID
- Event Severity
- DDOS Event Code:
EVT-NVRAM-000201(Critical) - iDRAC SDPM Event Codes and severity:
- Quick Reference:
- 5xxx errors → Informational
6xxx errors → Warning
7xxx errors → Critical
- 5xxx errors → Informational
-
iDRAC EVENT CODE SEVERITY: SDPM5198 - Diagnostic Event of Undefined Severity Informational SDPM5199 - Unknown Diagnostic Event Informational SDPM6101 - Diagnostic Warning (Configuration Check) Warning SDPM6199 - Unknown Diagnostic Warning Warning HWC8016 - SDPM Cable Issue Critical SDPM7101 - Critical Diagnostic Event (Configuration Check) Critical SDPM7106 - Critical Diagnostic Event (Contact Service Provider) Critical SDPM7107 - Critical Diagnostic Event (Retry Operation) Critical SDPM7108 - Critical Diagnostic Event (Sanitize Required) Critical SDPM7197 - Unsupported Fan Configuration Critical SDPM7199 - Unknown Critical Diagnostic Event Critical
- Quick Reference:
- DDOS Event Code:
Step 2: Perform Initial Health Validation:
Before investigating a specific SDPM event, verify overall appliance health.
Run:
-
alerts show currentdisk show statefilesys statussystem show nvram
Verify:
-
- No active disk failures
- No hardware faults unrelated to SDPM
- No recent unsupported hardware changes
- Appliance remains operational and filesystem is Up/Running
- iDRAC is running a Data Domain-approved firmware version
If the appliance reports additional hardware alerts, investigate those alongside the SDPM event since they may be related.
Step 3: Follow Event Specific Troubleshooting and Resolution Paths:
SDPM5198 – Diagnostic Event of Undefined Severity
Meaning: The installed iDRAC firmware cannot fully decode an SDPM diagnostic event.
Customer Actions:
-
-
- Record the location and Extended ID.
- Verify the current iDRAC firmware version.
- Update iDRAC to the latest Data Domain-approved release during the next maintenance window.
- Data Domain does NOT support out-of-band upgrades - the appropriate iDRAC version is bundled with every DDOS release.
- In order to update iDRAC to the latest, supported release, upgrade DDOS.
- Monitor for recurrence.
-
Most Likely Resolution: Updating iDRAC resolves the alert because the firmware gains the ability to properly interpret the reported SDPM event.
Escalate If: The event reappears after the firmware/DDOS update.
SDPM5199 – Unknown Diagnostic Event
Meaning: An SDPM event has been detected but the installed iDRAC firmware cannot decode it.
Customer Actions:
-
-
- Record the location and Extended ID.
- Verify the current iDRAC firmware version.
- Update iDRAC to the latest Data Domain-approved release during the next maintenance window.
- Data Domain does NOT support out-of-band upgrades - the appropriate iDRAC version is bundled with every DDOS release.
- In order to update iDRAC to the latest, supported release, upgrade DDOS.
- Monitor for recurrence.
-
Most Likely Resolution: Updating iDRAC resolves the alert because the firmware gains the ability to properly interpret the reported SDPM event.
Escalate If: The event reappears after the firmware/DDOS update.
SDPM6101– Diagnostic Warning (Configuration Check)
Meaning: The SDPM device may be operating in a degraded state due to a configuration inconsistency or developing hardware issue.
Customer Actions:
-
-
-
In iDRAC, review the System Event Log for correlated events.
-
From DDOS CLI Run:
system show hardware
alerts show current
system show nvram
filesystem status
-
-
Most Likely Resolution: A configuration mismatch is corrected or a degraded SDPM component is identified and replaced..
Escalate If: The warning persists after validation and reboot.
SDPM6199– Unknown Diagnostic Warning
Meaning: A warning-level SDPM event occurred, but the installed firmware cannot decode it.
Customer Actions:
-
-
- Record the location and Extended ID.
- Verify the current iDRAC firmware version.
- Update iDRAC to the latest Data Domain-approved release during the next maintenance window.
- Data Domain does NOT support out-of-band upgrades - the appropriate iDRAC version is bundled with every DDOS release.
- In order to update iDRAC to the latest, supported release, upgrade DDOS.
- Monitor for recurrence.
-
Most Likely Resolution: Updating iDRAC resolves the alert because the firmware gains the ability to properly interpret the reported SDPM event.
Escalate If: The event reappears after the firmware/DDOS update.
HWC8016– Critical SDPM Cable Issue
Meaning: A critical cable fault has been detected within the SDPM subsystem. Persistent memory save operations may fail.
Customer Actions:
-
-
- Verify critical backup operations complete successfully.
- Collect a support bundle and TSR immediately.
- Open a support case.
- Avoid unnecessary power cycling.
-
Most Likely Resolution:
-
-
- SDPM cable inspection
- SDPM cable reseating
- SDPM cable replacement
- SDPM hardware replacement (if required)
-
Escalate If: Data Domain filesystem is DOWN
SDPM7101– Critical Diagnostic Event (Configuration Check)
Meaning: The SDPM subsystem has reported a critical degraded-state condition.
Customer Actions:
-
-
- Review System Event Log entries.
- Check for correlated DDOS alerts.
- Verify platform configuration.
- Collect diagnostics.
-
Most Likely Resolution:
-
-
- Correction of an unsupported configuration or replacement of a failing SDPM component.
-
Escalate If: The event remains active after configuration validation.
SDPM7106– Critical Diagnostic Event (Contact Service Provider)
Meaning: The SDPM subsystem has reported a critical fault requiring further analysis.
Customer Actions:
-
-
- Review System Event Log entries.
- Collect a TSR.
- Generate a support bundle.
- Open a support case.
-
Most Likely Resolution:
-
-
- Support determines whether firmware remediation, SDPM component replacement, or additional hardware service is required.
-
Escalate If: Data Domain filesystem is DOWN.
SDPM7107– Critical Diagnostic Event (Retry Operation)
Meaning: An SDPM operation failed and could not complete successfully.
Customer Actions:
-
-
- Retry the affected operation once.
- Verify whether the alert clears.
- Review the SEL for additional SDPM events.
- Schedule a system reboot
-
Most Likely Resolution:
-
-
- A transient operation failure may clear after retry or reboot. Recurring events commonly indicate an underlying SDPM hardware issue.
-
Escalate If: The event returns after retrying the operation and rebooting the system.
SDPM7108– Critical Diagnostic Event (Sanitize Required)
Meaning: The SDPM device contains unusable configuration data or detected an unrecoverable startup condition. Often encountered after SDPM Module replacement.
Customer Actions:
-
-
- Review System Event Log entries.
- Proceed to re-initialize and sanitize SDPM Storage: Data Domain: How to Reinitialize and Sanitize SDPM | NVRAM (alt: Video
Example of process on PowerFlex system)
-
Most Likely Resolution:
-
-
- SDPM sanitization and reinitialization clears the alert and no further action is required.
-
Escalate If: Alerts persist after sanitization was performed OR filesystem will not enable (Tech Support my need to bypass stale NVRAM).
SDPM7197– Unsupported Fan Configuration
Meaning: The platform does not detect the high-performance fan configuration required by SDPM.
Customer Actions:
-
-
- Review recent component replacement activities.
- Verify no unsupported hardware changes occurred.
-
Most Likely Resolution:
-
-
- Replacement of non-compliant fan modules with the correct Dell-qualified high-performance fan assemblies.
-
SDPM7199– Unknown Critical Diagnostic Event
Meaning: A critical SDPM event occurred but cannot be decoded by the installed iDRAC firmware.
Customer Actions:
-
-
- Review and collect System Event Log entries.
- Verify the current iDRAC firmware version.
- Update iDRAC to the latest Data Domain-approved release during the next maintenance window.
- Data Domain does NOT support out-of-band upgrades - the appropriate iDRAC version is bundled with every DDOS release.
- In order to update iDRAC to the latest, supported release, upgrade DDOS.
- Monitor for recurrence.
-
Most Likely Resolution:
-
-
- Updating iDRAC resolves the alert because the firmware gains the ability to properly interpret the reported SDPM event.
-
Escalate If: The event reappears after the firmware/DDOS update.
Step 4: Collecting Diagnostic Data:
- Create a DDOS Support Bundle, from CLI:
support bundle create default - Create an iDRAC TSR:
RACADM:racadm techsupreport collect - iDRAC GUI:
Maintenance → SupportAssist → Start a Collection
Provide the generated files when opening a support case.
Step 5: Escalation Criteria:
-
- Any SDPM7xxx event remains active after remediation attempts.
- Backup or restore operations are affected.
- An SDPM event reappears after firmware updates and reboot.
その他の情報
References:
iDRAC (v7.x) Error and Event Messages Reference Guide (search 'sdpm')
Data Domain: How to Reinitialize and Sanitize SDPM | NVRAM