Avamar: Administrator UI reports an incorrect Data Domain status due to firewall or port issues

요약: Incorrect firewall and port settings can cause SNMP issues.

이 문서는 다음에 적용됩니다. 이 문서는 다음에 적용되지 않습니다. 이 문서는 특정 제품과 관련이 없습니다. 모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.

증상

This is a monitoring issue.

This issue does not affect backups from Avamar to Data Domain (DD).

If backups are failing when Data Domain monitoring status is not reporting OK, stop following this article.
 

Avamar monitoring status for Data Domain changes to Yellow or Red from Green on the Avamar Administrator UI

 

One or more of the following errors may appear in the Avamar UI:
  • Error: Unable to get SNMP file system status
  • Error: Unable to get file system information
  • Error: Unable to get disk status
  • Error: Unable to retrieve ssh keys

 

 

원인

The required ports for Simple Network Management Protocol (SNMP) are not satisfied in the Avamar or Data Domain environment.

-- Or --

A firewall, or firewalls between Avamar and Data Domain are filtering (blocking) one or more of the SNMP packets.

해결

Ensure that port 163 is open.

Ensure that trap port 161 (default), or 162 is open.

Note: As SNMP uses UDP ports, using telnet or curl is not a viable option to check whether these ports are open.
 

If the issue remains unresolved, see the resolution path for SNMP issues: Avamar: Troubleshooting Data Domain Integration Errors in the Avamar Administrator UI (Resolution Path)