ECS: GUI Error 6500 (http: 500): Internal Server Error. An internal server error occurred.

Sammendrag: This knowledge article explains why the ECS UI is unable to log in due login Error 6500 (http: 500): Internal Server Error. An internal server error occurred. Please try again.

Denne artikkelen gjelder for Denne artikkelen gjelder ikke for Denne artikkelen er ikke knyttet til noe bestemt produkt. Det er ikke produktversjonene som identifiseres i denne artikkelen.

Symptomer

When logging into the UI on a specific node, the following error is seen on the dashboard or end user license agreement notification:
error 6500

 

Årsak

There are three ECS services responsible for UI login, stat, "ecsportalsvc," and "obcontrolsvc" - these have stale entries which are not allowing the UI to log in.

 

Oppløsning

On the concerning node, restart the stat, ecsportalsvc, and obcontrolsvc. There is no impact on restarting these services but it should be noted that any alerts generated on the UI on another node are now linked to these restarts:

 

Using service tools:

admin@node1:~> svc_node services restart -nw 10 -srv stat ecsportalsvc objcontrolsvc -n self
Starting utility inside a screen session

 

Confirm on the concerning node (rack 1 node 1) that the services have restarted and ensure that there are no services that are not running:

admin@node1:~> svc_node services -status
svc_node v1.2.1 (svc_tools v2.1.0)                 Started 2022-02-25 11:40:49

Node r1n1:
    Services running:
        fabric-agent

        blobsvc        (102925) Started: 2021-12-20 17:07:17      cm             (102859) Started: 2021-12-20 17:07:17
        coordinatorsvc (102843) Started: 2021-12-20 17:07:17      dataheadsvc    (102935) Started: 2021-12-20 17:07:17
        dtquery        (102951) Started: 2021-12-20 17:07:17      ecsportalsvc   (66505)  Started: 2022-02-25 11:31:08
        eventsvc       (102932) Started: 2021-12-20 17:07:17      georeceiver    (102950) Started: 2021-12-20 17:07:17
        metering       (102908) Started: 2021-12-20 17:07:17      objcontrolsvc  (69329)  Started: 2022-02-25 11:31:32
        resourcesvc    (102939) Started: 2021-12-20 17:07:17      rm             (102851) Started: 2021-12-20 17:07:17
        sr             (102905) Started: 2021-12-20 17:07:17      ssm            (102899) Started: 2021-12-20 17:07:17
        stat           (65535)  Started: 2022-02-25 11:30:55      storageserver  (102896) Started: 2021-12-20 17:07:17
        vnest          (102847) Started: 2021-12-20 17:07:17

    Services not running:
        <none>

 

Return to the ECS UI and you can log in without issue.

 

Berørte produkter

ECS

Produkter

ECS Appliance, ECS Appliance Gen 1, ECS Appliance Gen 2, ECS Appliance Gen 3
Artikkelegenskaper
Artikkelnummer: 000196746
Artikkeltype: Solution
Sist endret: 13 mai 2026
Versjon:  9
Få svar på spørsmålene dine fra andre Dell-brukere
Støttetjenester
Sjekk om enheten din er dekket av støttetjenestene.