When Dell PowerStore encounters a problem, an error alert is generated to help identify the issue. This article explains the different possible causes and the relevant solutions for these error alerts. If your problem is not resolved despite the solution provided, check the technical support contact options.

 

SLN321963_en_US__1icon Note: Cannot find the information you need? Let us know via the feedback form at the bottom of this article.


 

Alert ID NODE_TIME_SYNC_STATUS_HUGE_DIFF
Alert Text Time difference between the node and the following available NTP servers is huge
Error Code (0x01806D03)
Description During the Initial Configuration process, the user is required to enter one or more NTP server addresses for time synchronization. The  NODE_TIME_SYNC_STATUS_HUGE_DIFF alert is raised when the time difference between the node and available NTP server is greater than five(5) minutes. 
If this issue persists, then time synchronization on the node may continue to break apart and replication sessions may be affected.
Resolution To resolve this issue, invoke the 'svc_ntp_ctl' service script on the node for forced synchronization of node time with configured NTP servers and ensure that time difference between the node and configured NTP servers.
1.  Verify the status of the ntp service svc_ntp_ctl
2.  Run the service script to force the synchronization of the node’s time: run svc_ntp_ctl --server <ip address of NTP server>
 
In PowerStore 1.x and 3.x, and above, you can use svc_ntp_ctl --set for the same result. 
 

 

Causa

   

Resolução

   

Mais informações

Additional similar error:

Status of synchronization between the node and available NTP servers. (large_diff)