PowerFlex 3.X: Error Parsing CSV: The amount of NVDIMMM devices mismatches the amount of its acceleration pools

Resumo: When uploading a PowerFlex CSV file with multiple NVDIMM Acceleration Devices assigned with the Acceleration pool defined once. You receive the following error. "Error Parsing CSV: The amount of NVDIMM devices mismatches the amount of its acceleration pools. Ensure the number of NVDIMM devices matches the number of its acceleration pools." ...

Este artigo aplica-se a Este artigo não se aplica a Este artigo não está vinculado a nenhum produto específico. Nem todas as versões do produto estão identificadas neste artigo.

Instruções

Scenario:  User configures CSV to deploy a PowerFlex cluster using the PowerFlex Gateway/Installer.

PowerFlex Gateway/Installer. 
User selects configured CSV and clicks "Upload installation CSV"

User receives the following error.

The amount of NVDIMMM devices mismatches the amount of its acceleration pools 

Reason for Error
The error points to a configuration issue with the configuration for the CSV "comma-separated value" configuration for the number of acceleration devices compared to the defined Acceleration Pool List. The CSV file had three Acceleration devices defined but only defined the Acceleration Pool once. For the configuration to validate. You need a 1 to 1 configuration definition for dax to acceleration pool.

Problem
Example configuration that would trigger this error.

NVDIMM Acceleration Device List
/dev/dax0.0,/dev/dax1.0,/dev/dax2.0

NVDIMM Acceleration Pool List
AccPoo101

 

Solution
Configuration that passes validation. 

NVDIMM Acceleration Device List
/dev/dax0.0,/dev/dax1.0,/dev/dax2.0

NVDIMM Acceleration Pool List
AccPoo101,AccPoo101,AccPoo101


Validation

image.png

Propriedades do artigo
Número do artigo: 000216219
Tipo de artigo: How To
Último modificado: 17 dez. 2025
Versão:  3
Encontre as respostas de outros usuários da Dell para suas perguntas.
Serviços de suporte
Verifique se o dispositivo está coberto pelos serviços de suporte.