PowerStore: System health check detects a target port group issue that may affect mapping of an NVMeoF volume
Resumo: Mapping an NVMeoF volume may lead to service disruption if there had been Add Appliances failures beforehand. The System Health check detects a target port group issue that may result in a service disruption while mapping an NVMeoF volume. ...
Este artigo aplica-se a
Este artigo não se aplica a
Este artigo não está vinculado a nenhum produto específico.
Nem todas as versões do produto estão identificadas neste artigo.
Sintomas
The System Check in the off-release health check package may identify an invalid target group id. This issue is described in KB 000216639 PowerStore: Mapping an NVMeoF volume may lead to service disruption on multi-appliance clusters.
The issue is detected in the following scenarios:
The issue is detected in the following scenarios:
- Running a System Check using PowerStore Manager (UI) with the Run System Check option:
- Running the System Health Service Script (svc_health_check) using an SSH connection: Note: Output truncated for illustrative purposes.
| [SVC:cyc@ABCDEF-A ~]$ svc_health_check run -rhc target_port_group_id_check Name Location Status Description Target PortGroup Id Check node_a Failed Max value of LOCAL target_port_group_id is over the max threshold of 29. (KB000216953) |
Causa
After multiple add appliance failures, the target group id may be assigned a value outside of the valid range. This will impact the cluster when NVMEoF host mapping is being used.
Resolução
Contact technical support for assistance in resolving this issue. This should be resolved ASAP.
If not resolved, there is a high risk of the node may enter service mode or go down affecting the High Availability of the appliance.
This issue is planned to be resolved in a future PowerStoreOS release.
If not resolved, there is a high risk of the node may enter service mode or go down affecting the High Availability of the appliance.
This issue is planned to be resolved in a future PowerStoreOS release.
Mais informações
KB 000198084 PowerStore: How to use the System Check feature.
KB 000214752 PowerStore: Landing Page for In Market (off-release) System Health Checks is a public facing KB with a listing of all the health checks.
KB 000216639 PowerStore: Mapping an NVMeoF volume may lead to service disruption on multi-appliance clusters.
KB 000214752 PowerStore: Landing Page for In Market (off-release) System Health Checks is a public facing KB with a listing of all the health checks.
KB 000216639 PowerStore: Mapping an NVMeoF volume may lead to service disruption on multi-appliance clusters.
Produtos afetados
PowerStorePropriedades do artigo
Número do artigo: 000216953
Tipo de artigo: Solution
Último modificado: 14 jun. 2025
Versão: 4
Encontre as respostas de outros usuários da Dell para suas perguntas.
Serviços de suporte
Verifique se o dispositivo está coberto pelos serviços de suporte.