PowerStore: System Check detects unnecessary de-stages

Resumo: The System Check detects if there are unnecessary de-stages, which may lead to excessive drive wear.

Este artigo aplica-se a Este artigo não se aplica a Este artigo não está vinculado a nenhum produto específico. Nem todas as versões do produto estão identificadas neste artigo.

Sintomas

If the System Check detects the excessive wear issue, the following error message is displayed: "Possible issue causing excessive wear on drives is detected. (KB#000220203)"

Screenshot of the PowerStore Manager:image.png

When detected by the service script svc_health_check:
[...@ABCDEF-A ~]$ svc_health_check run -rhc dp_dedupe_destage_leak_check
Name                               Location  Status     Description
Datapath Dedup Destage Leak        node_a    Failed     Possible issue causing excessive wear on drives is detected. (KB#000220203)
Datapath Dedup Destage Leak        node_b    Failed     Possible issue causing excessive wear on drives is detected. (KB#000220203)
 
 
SUMMARY Status: Failed
   Passed:      0
   Failed:      2
   Total:       2
 

Causa

The system check detects the issue of KB 000206257 PowerStore: NVMe SSD may wear faster due to increased write amplification.

The issue is resolved in 3.6 and later.

Resolução

If the issue is detected, upgrade to 3.6 or later.
If upgrade to 3.6 cannot be performed in the near future, contact technical support for assistance. Reference this KB Article for expedited handling. A script can be run to remedy the excessive drive wear from occurring in the future.

Mais informações

Produtos afetados

PowerStore
Propriedades do artigo
Número do artigo: 000220203
Tipo de artigo: Solution
Último modificado: 14 jun. 2025
Versão:  3
Encontre as respostas de outros usuários da Dell para suas perguntas.
Serviços de suporte
Verifique se o dispositivo está coberto pelos serviços de suporte.