PowerStore: System Check detects unnecessary de-stages
Resumo: The System Check detects if there are unnecessary de-stages, which may lead to excessive drive wear.
Este artigo aplica-se a
Este artigo não se aplica a
Este artigo não está vinculado a nenhum produto específico.
Nem todas as versões do produto estão identificadas neste artigo.
Sintomas
If the System Check detects the excessive wear issue, the following error message is displayed: "Possible issue causing excessive wear on drives is detected. (KB#000220203)"
Screenshot of the PowerStore Manager:
When detected by the service script svc_health_check:
Screenshot of the PowerStore Manager:
When detected by the service script svc_health_check:
[...@ABCDEF-A ~]$ svc_health_check run -rhc dp_dedupe_destage_leak_check Name Location Status Description Datapath Dedup Destage Leak node_a Failed Possible issue causing excessive wear on drives is detected. (KB#000220203) Datapath Dedup Destage Leak node_b Failed Possible issue causing excessive wear on drives is detected. (KB#000220203) SUMMARY Status: Failed Passed: 0 Failed: 2 Total: 2
Causa
The system check detects the issue of KB 000206257 PowerStore: NVMe SSD may wear faster due to increased write amplification.
The issue is resolved in 3.6 and later.
The issue is resolved in 3.6 and later.
Resolução
If the issue is detected, upgrade to 3.6 or later.
If upgrade to 3.6 cannot be performed in the near future, contact technical support for assistance. Reference this KB Article for expedited handling. A script can be run to remedy the excessive drive wear from occurring in the future.
If upgrade to 3.6 cannot be performed in the near future, contact technical support for assistance. Reference this KB Article for expedited handling. A script can be run to remedy the excessive drive wear from occurring in the future.
Mais informações
KB 000192601 PowerStore: How to Check the Health of the Cluster Before Software Upgrade Using Pre-Upgrade Health Check and System Check.
KB 000214752 PowerStore: Landing Page for In Market (off-release) System Health Checks lists all the health checks in the Health Check thin package.
KB 000214752 PowerStore: Landing Page for In Market (off-release) System Health Checks lists all the health checks in the Health Check thin package.
Produtos afetados
PowerStorePropriedades do artigo
Número do artigo: 000220203
Tipo de artigo: Solution
Último modificado: 14 jun. 2025
Versão: 3
Encontre as respostas de outros usuários da Dell para suas perguntas.
Serviços de suporte
Verifique se o dispositivo está coberto pelos serviços de suporte.