PowerScale: Isilon: OneFS: How to install and run internal_ping script to test back-end network connectivity

Sammanfattning: This "How to" article explains the process to setup and run internal_ping script to test the back-end mesh connectivity for both Ethernet and InfiniBand networks.

Den här artikeln gäller för Den här artikeln gäller inte för Den här artikeln är inte kopplad till någon specifik produkt. Alla produktversioner identifieras inte i den här artikeln.

Instruktioner

There is a single-line shell script, or run through most current OneFS health check script.

One line option:       

FILE=/ifs/data/Isilon_Support/backendpingtest.txt; echo "" > $FILE; isi_for_array -XI 'for i in $(isi_nodes %{name}":"%{internal_a_address}":"%{internal_b_address}":"%{failover}); do name=$(echo $i | cut -f 1 -d ":"); if [ "$name" != "$(hostname)" ]; then iba=$(echo $i | cut -f 2 -d":"); ibb=$(echo $i | cut -f 3 -d":"); ibf=$(echo $i | cut -f 4 -d":"); ping -c2 -t2 $iba > /dev/null; if [ $? -eq 0 ]; then iba_ok="|A| _OK_ "; else iba_ok="|A| FAIL "; fi; ping -c2 -t2 $ibb > /dev/null; if [ $? -eq 0 ]; then ibb_ok="|B| _OK_ "; else ibb_ok="|B| FAIL "; fi; ping -c2 -t2 $ibf > /dev/null; if [ $? -eq 0 ]; then ibf_ok="|F| _OK_ "; else ibf_ok="|F| FAIL "; fi; echo -e "-> :$name\t$iba_ok\t$ibb_ok\t$ibf_ok"; fi; done' >> $FILE && clear; cat $FILE | sort -k1,3 -V | grep -v "Host is down" | tee /ifs/data/Isilon_Support/backendpingtest-$(date +%F_%H%M%S).txt

Let the command run through. If you want to stop the command early, run CTRL-C. If it does not print anything, it does not mean it is not working.

Ytterligare information

This can be run anytime on the cluster and must be run on a single node.

Isilon-1: -> :Isilon-2   |A| _OK_  |B| _OK_  |F| _OK_ 
Isilon-1: -> :Isilon-3   |A| _OK_  |B| _OK_  |F| _OK_ 
Isilon-1: -> :Isilon-4   |A| _OK_  |B| _OK_  |F| _OK_
Isilon-2: -> :Isilon-1   |A| _OK_  |B| _OK_  |F| _OK_ 
Isilon-2: -> :Isilon-3   |A| _OK_  |B| _OK_  |F| _OK_ 
Isilon-2: -> :Isilon-4   |A| _OK_  |B| _OK_  |F| _OK_
Isilon-3: -> :Isilon-1   |A| _OK_  |B| _OK_  |F| _OK_ 
Isilon-3: -> :Isilon-2   |A| _OK_  |B| _OK_  |F| _OK_ 
Isilon-3: -> :Isilon-4   |A| _OK_  |B| _OK_  |F| _OK_
Isilon-4: -> :Isilon-1   |A| _OK_  |B| _OK_  |F| _OK_
Isilon-4: -> :Isilon-2   |A| _OK_  |B| _OK_  |F| _OK_
Isilon-4: -> :Isilon-3   |A| _OK_  |B| _OK_  |F| _OK_

Berörda produkter

PowerScale OneFS
Artikelegenskaper
Artikelnummer: 000158347
Artikeltyp: How To
Senast ändrad: 25 sep. 2025
Version:  9