PowerStore: Node May Reboot Unexpectedly from a Linux Driver Memory Leak
摘要: A node may reset unexpectedly due to a memory leak within kernel space for SCSI Target (SCST) Report LUNs response.
本文适用于
本文不适用于
本文并非针对某种特定的产品。
本文并非包含所有产品版本。
症状
The system reports excessive messages such as:
A useful command to check the number of these messages is, for example:
Indications of starvation may start coming up in the logs:
A dump file is created for this event but it is not required for the Root Cause Analysis (RCA). See svc_dc list_dumps.
svc_journalctl | grep "REPORT LUNS" |
A useful command to check the number of these messages is, for example:
svc_journalctl --since="today" | grep -c "REPORT LUNS" |
Indications of starvation may start coming up in the logs:
svc_journalctl --since="today" | grep -i starved |
A dump file is created for this event but it is not required for the Root Cause Analysis (RCA). See svc_dc list_dumps.
原因
This issue happens due to a memory leak within the kernel space for SCST due to excessive "Report LUN" commands from ESXi. This may cause a delay in keepalive communication between nodes triggering a node reset.
解决方案
This issue is resolved in PowerStoreOS 1.0.4.0.5.006 (V1 SP4.1).
The fix is listed in the release notes under MDT-261192: A node may reboot unexpectedly, due to a Linux driver memory leak.
The fix is listed in the release notes under MDT-261192: A node may reboot unexpectedly, due to a Linux driver memory leak.
受影响的产品
PowerStore, PowerStore 1000X, PowerStore 1000T, PowerStore 3000X, PowerStore 3000T, PowerStore 5000X, PowerStore 5000T, PowerStore 7000X, PowerStore 7000T, PowerStore 9000T产品
PowerStore 9000X文章属性
文章编号: 000185532
文章类型: Solution
上次修改时间: 04 11月 2021
版本: 5
从其他戴尔用户那里查找问题的答案
支持服务
检查您的设备是否在支持服务涵盖的范围内。