PowerStore: Unexpected internal software module restart when Metro Volume is configured with snapshot rules
摘要: One of the software modules may unexpectedly restart due to a timing issue when the PowerStore appliance is using the Metro Volume and on that Metro volume, a snapshot rule is configured. ...
本文适用于
本文不适用于
本文并非针对某种特定的产品。
本文并非包含所有产品版本。
症状
Aמ internal software module in a PowerStore appliance may unexpectedly restart due to a timing issue when the following occur simultaneously:
This issue only affects customers who are using Metro Volume and on a Metro volume there are snapshot rules configured.
- The appliance is using the Metro Volume feature
- And on a Metro volume a snapshot rule is configured.
This issue only affects customers who are using Metro Volume and on a Metro volume there are snapshot rules configured.
原因
This is a timing issue during the snapshot creation and write operations that may lead, under rare circumstances, to an unexpected software module restart.
解决方案
This issue is fixed PowerStoreOS 3.6.x.
Workaround
If assistance is required to verify that the issue encountered is the root cause described in this article, contact Dell Global Support.
If the issue persists, consider removing the snapshots schedule for the affected metro volume.
Workaround
If assistance is required to verify that the issue encountered is the root cause described in this article, contact Dell Global Support.
If the issue persists, consider removing the snapshots schedule for the affected metro volume.
其他信息
For more information about the Metro Volume feature, see Introduction of PowerStore Metro Volume.