Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell Chassis Management Controller Version 3.0 for PowerEdge VRTX RACADM CLI Guide

PDF

get controllers

Description

The command lists all RAID controllers detected in the system and their properties.
NOTE To use this subcommand, you must have the CMC Login User privilege.

Synopsis

raid get controllers -o

Input

  • -o — The -o is used to display the fault-tolerant status of a RAID controller.

Example

Sample output of a CMC in which either fault-tolerant mode is not available or is not enabled.

RAID.ChassisIntegrated.1-1
Status                     = Ok
RollupStatus               = Ok
Name                       = Shared PERC8 (Embedded)
FirmwareVersion            = 23.8.3-0027
DriverVersion              = 06.802.11.00
RebuildRate                = 30 %
BgiRate                    = 35 %
CheckConsistencyRate       = 40 %
ReconstructRate            = 30 %
PatrolReadRate             = 30 %
PatrolReadMode             = Manual
PatrolReadState            = Stopped
CheckConsistencyMode       = Stop On Error
LoadBalanceSetting         = Disabled
CopybackMode               = OFF
PreservedCache             = Not Present
CacheMemorySize            = 1024 MB
PersistHotspare            = Disabled
SpindownUnconfiguredDrives = Disabled
SpindownHotspare           = Disabled
Timeintervalforspindown    = 30 (Minutes)
SecurityStatus             = Unknown
EncryptionMode             = None
SasAddress                 = 0x590B11C02620E600
PciDeviceId                = 0x2f
PciSubdeviceId             = 0x1f3e
PciVendorId                = 0x1000
PciSubvendorId             = 0x1028
PciBus                     = 0x0
PciDevice                  = 0x0
PciFunction                = 0x0
BusWidth                   = Unknown
SlotLength                 = Short
SlotType                   = Unknown
CapableSpeeds              = 6.0 Gb/s, 3.0 Gb/s
LearnMode                  = Not supported
HighAvailabilityMode       = None
PeerController			= N/A                  
Sample output of a CMC in which you have firmware support for the fault-tolerant mode and the hardware, and fault-tolerant mode is active.
RAID.ChassisIntegrated.1-1
Status                      = Ok
RollupStatus                = Ok
Name                        = Shared PERC8 (Embedded)
FirmwareVersion             = 23.8.3-0027
DriverVersion               = 06.802.11.00
RebuildRate                 = 30 %
BgiRate                     = 35 %
CheckConsistencyRate        = 40 %
ReconstructRate             = 30 %
PatrolReadRate              = 30 %
PatrolReadMode              = Manual
PatrolReadState             = Stopped
CheckConsistencyMode        = Stop On Error
LoadBalanceSetting          = Disabled
CopybackMode                = OFF
PreservedCache              = Not Present
CacheMemorySize             = 1024 MB
PersistHotspare             = Disabled
SpindownUnconfiguredDrives  = Disabled
SpindownHotspare            = Disabled
Timeintervalforspindown     = 30 (Minutes)
SecurityStatus              = Unknown
EncryptionMode              = None
SasAddress                  = 0x590B11C02620E600
PciDeviceId                 = 0x2f
PciSubdeviceId              = 0x1f3e
PciVendorId                 = 0x1000
PciSubvendorId              = 0x1028
PciBus                      = 0x0
PciDevice                   = 0x0
PciFunction                 = 0x0
BusWidth                    = Unknown
SlotLength                  = Short
SlotType                    = Unknown
CapableSpeeds               = 6.0 Gb/s, 3.0 Gb/s
LearnMode                   = Not supported
HighAvailabilityMode     	= Fault Tolerant(Active/Passive)
PeerController				= RAID.ChassisIntegrated.2-1                  
RAID.ChassisIntegrated.2-1
Status                      = Ok
RollupStatus                = Ok
Name                        = Shared PERC8 (Embedded)
FirmwareVersion             = 23.8.3-0027
DriverVersion               = 06.802.11.00
RebuildRate                 = 30 %
BgiRate                     = 35 %
CheckConsistencyRate        = 40 %
ReconstructRate             = 30 %
PatrolReadRate              = 30 %
PatrolReadMode              = Manual
PatrolReadState             = Stopped
CheckConsistencyMode        = Stop On Error
LoadBalanceSetting          = Disabled
CopybackMode                = OFF
PreservedCache              = Not Present
CacheMemorySize             = 1024 MB
PersistHotspare             = Disabled
SpindownUnconfiguredDrives  = Disabled
SpindownHotspare            = Disabled
Timeintervalforspindown     = 30 (Minutes)
SecurityStatus              = Unknown
EncryptionMode              = None
SasAddress                  = 0x590B11C02620E600
PciDeviceId                 = 0x2f
PciSubdeviceId              = 0x1f3e
PciVendorId                 = 0x1000
PciSubvendorId              = 0x1028
PciBus                      = 0x0
PciDevice                   = 0x0
PciFunction                 = 0x0
BusWidth                    = Unknown
SlotLength                  = Short
SlotType                    = Unknown
CapableSpeeds               = 6.0 Gb/s, 3.0 Gb/s
LearnMode                   = Not supported
HighAvailabilityMode        = Fault Tolerant(Active/Passive)
PeerController				= RAID.ChassisIntegrated.1-1                  

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\